Quoting Juergen Schoenwaelder <schoenw@ibr.cs.tu-bs.de>:
> Fixed in the main CVS now. Should show up in the anon CVS repository
> soon.
this is working well now
> Max> X Error of failed request: BadAlloc (insufficient resources
> Max> for operation) Major opcode of failed request: 1 (X_CreateWindow)
> Max> Serial number of failed request: 5774 Current serial number in
> Max> output stream: 9278
> Hm. Not sure who is responsible for this fault here.
it mysteriously stopped doing this.
> Max> 3) What should go in the Time base field of the Monitor Variable
> Max> dialog box?
>
> Usually, the time base / discontinuity indicator this is just
> sysUpTime, which is the default. (Some counters have their own time
> base - but most people/tools seem do not care about these details
> anyway ;-).
Like I posted before, the main problem I had with this is that it wouldn't
recognize sysUpTime.0 variable as type TimeTicks. Commenting out the check for
TimeTicks in snmp_monitor.tcl allowed me to create all the stripcharts I
wanted. Any idea?
Thanks again for all your help.
--mk23
-- !! This message is brought to you via the `tkined & scotty' mailing list. !! Please do not reply to this message to unsubscribe. To subscribe or !! unsubscribe, send a mail message to <tkined-request@ibr.cs.tu-bs.de>. !! See http://wwwsnmp.cs.utwente.nl/~schoenw/scotty/ for more information.
This archive was generated by hypermail 2b29 : Thu Jan 03 2002 - 14:56:26 MET