This memo presents a language for management information specifications. It eliminates known problems present in the current SMIv2 as specified in [2], [3], and [4]. Language extensibility features and a more efficient and programmer-friendly notation are introduced. Conversions from SMIv2 to SMIng and vice versa are also considered by this document.
Copyright (C) The Internet Society (1999). All Rights Reserved.
TOC |
1. | Introduction |
1.1 | Terminology |
1.2 | Relation to SNMP |
2. | The Information Model |
2.1 | Identifiers |
2.2 | Object Identifier Hierarchy |
2.3 | Kinds of Nodes |
2.4 | Scalar and Columnar Objects' Instances |
3. | Base Types and Derived Types |
3.1 | OctetString |
3.2 | ObjectIdentifier |
3.3 | Integer32 |
3.4 | Integer64 |
3.5 | Unsigned32 |
3.6 | Unsigned64 |
3.7 | Float32 |
3.8 | Float64 |
3.9 | Float128 |
3.10 | Enumeration |
3.11 | Bits |
3.12 | Display Formats |
4. | The SMIng File Structure |
4.1 | Comments |
4.2 | Statements and Arguments |
5. | The module Statement |
5.1 | The module's import Statement |
5.2 | The module's oid Statement |
5.3 | The module's organization Statement |
5.4 | The module's contact Statement |
5.5 | The module's description Statement |
5.6 | The module's reference Statement |
5.7 | The module's revision Statement |
5.7.1 | The revision's date Statement |
5.7.2 | The revision's description Statement |
5.8 | Usage Example |
6. | The extension Statement |
6.1 | The extension's status Statement |
6.2 | The extension's description Statement |
6.3 | The extension's reference Statement |
7. | The typedef Statement |
7.1 | The typedef's type Statement |
7.2 | The typedef's default Statement |
7.3 | The typedef's format Statement |
7.4 | The typedef's units Statement |
7.5 | The typedef's status Statement |
7.6 | The typedef's description Statement |
7.7 | The typedef's reference Statement |
7.8 | Usage Examples |
8. | The node Statement |
8.1 | The node's oid Statement |
8.2 | The node's status Statement |
8.3 | The node's description Statement |
8.4 | The node's reference Statement |
8.5 | Usage Examples |
9. | The scalar Statement |
9.1 | The scalar's oid Statement |
9.2 | The scalar's type Statement |
9.3 | The scalar's access Statement |
9.4 | The scalar's default Statement |
9.5 | The scalar's format Statement |
9.6 | The scalar's units Statement |
9.7 | The scalar's status Statement |
9.8 | The scalar's description Statement |
9.9 | The scalar's reference Statement |
9.10 | Usage Examples |
10. | The table Statement |
10.1 | The table's oid Statement |
10.2 | The table's status Statement |
10.3 | The table's description Statement |
10.4 | The table's reference Statement |
10.5 | The table's row Statement |
10.5.1 | The row's oid Statement |
10.5.2 | Table Indexing Statements |
10.5.2.1 | The row's index Statement for Table Indexing |
10.5.2.2 | The row's augments Statement for Table Indexing |
10.5.2.3 | The row's sparse Statement for Table Indexing |
10.5.2.4 | The row's reorders Statement for Table Indexing |
10.5.2.5 | The row's expands Statement for Table Indexing |
10.5.3 | The row's create Statement |
10.5.4 | The row's status Statement |
10.5.5 | The row's description Statement |
10.5.6 | The row's reference Statement |
10.6 | The table row's column Statement |
10.6.1 | The column's oid Statement |
10.6.2 | The column's type Statement |
10.6.3 | The column's access Statement |
10.6.4 | The column's default Statement |
10.6.5 | The column's format Statement |
10.6.6 | The column's units Statement |
10.6.7 | The column's status Statement |
10.6.8 | The column's description Statement |
10.6.9 | The column's reference Statement |
10.7 | Usage Example |
11. | The notification Statement |
11.1 | The notification's oid Statement |
11.2 | The notification's objects Statement |
11.3 | The notification's status Statement |
11.4 | The notification's description Statement |
11.5 | The notification's reference Statement |
11.6 | Usage Example |
12. | The group Statement |
12.1 | The group's oid Statement |
12.2 | The group's members Statement |
12.3 | The group's status Statement |
12.4 | The group's description Statement |
12.5 | The group's reference Statement |
12.6 | Usage Example |
13. | The compliance Statement |
13.1 | The compliance's oid Statement |
13.2 | The compliance's status Statement |
13.3 | The compliance's description Statement |
13.4 | The compliance's reference Statement |
13.5 | The compliance's mandatory Statement |
13.6 | The compliance's optional Statement |
13.6.1 | The optional's description Statement |
13.7 | The compliance's refine Statement |
13.7.1 | The refine's type Statement |
13.7.2 | The refine's writetype Statement |
13.7.3 | The refine's access Statement |
13.7.4 | The refine's description Statement |
13.8 | Usage Example |
14. | SMIng Core Modules |
14.1 | IRTF-NMRG-SMING |
14.2 | IRTF-NMRG-SMING-TYPES |
14.3 | IRTF-NMRG-SMING-EXTENSIONS |
15. | Extending a Module |
16. | SMIng Language Extensibility |
17. | Module Conversions |
17.1 | Converting SMIv2 to SMIng |
17.2 | Converting SMIng to SMIv2 |
17.3 | SMIv1 |
18. | Security Considerations |
19. | Acknowledgements |
§ | References |
§ | Author's Address |
A. | The SMIng ABNF grammar |
B. | Glossary |
TOC |
Management information is viewed as a collection of managed objects, residing in a virtual information store, termed the Management Information Base (MIB). Collections of related objects are defined in MIB modules. These modules are written conforming to a specification language, the Structure of Management Information (SMI). There are different versions of the SMI. SMIv1 [5], [6], [7] and SMIv2 [2], [3], [4] are based on adapted subsets of OSI's Abstract Syntax Notation One, ASN.1 [9]. It is the purpose of this document to define a successor of SMIv1 and SMIv2, the SMIng, in a self-contained way independent from other standardization bodies' documents.
The Information Model gives an overview of the information model without respect to the SMIng language while the subsequent sections present the concepts of SMIng: the base types, the SMIng file structure, and all SMIng statements in detail. SMIng Core Modules contains two core modules that are part of the SMIng specification. Extending a Module lists rules to follow when changes are applied to a module. One flexible feature of SMIng is its extensibility which is described in SMIng Language Extensibility. Finally, Module Conversions discusses conversions of SMIv2 modules to SMIng and vice versa. The SMIng ABNF grammar contains the grammar of SMIng in ABNF [8] notation.
Many terms in SMIv1 and SMIv2 are derived from ASN.1. In some cases, SMIv1/v2 uses different terms for equal or similar language items without precise definitions. Glossary presents a glossary of terms used throughout this document and in related SMIng documents. Also refer to the glossary and The SMIng ABNF grammar to get detailed information on the syntax of single language items where not explained in place.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [1].
Although SMIng is primarily intended to be applied to the the SNMP management framework [10], the information model represented by SMIng is designed to have as few relations to a specific management protocol as possible. However, there are some implications of SNMP on SMIv2 that have to be retained in SMIng:
TOC |
Internet management is based on the model of "managed objects". A managed object represents a class of any real or synthesized variable of systems that are to be managed. Those objects are organized hierarchically in an "object identifier tree", where only leaf nodes may represent objects.
Nodes may also identify tables, row definitions of tables, notifications, groups of objects and/or notifications, compliance statements, modules or other information. Each node is identified by an unique "object identifier" value which is an ordered list of non-negative numbers, named "sub-identifiers", where the left-most sub-identifier refers to the node next to the root of the tree and the right-most sub-identifier refers to the node that is identified by the complete object identifier.
The SMI in general, and SMIng in particular, is the information model used to define and organize the structure of managed objects and related information. Thus, SMIng describes a language designed to specify management information in a way readable to computer programs, named MIB compilers, as well as to human readers.
Related management information is defined in MIB modules. A module may refer to definitions from other modules by importing the required identifiers from those modules. Each module may serve one or multiple purposes:
This classification scheme does not imply a rigid taxonomy. For example, a "standard" module will normally include definitions of managed objects and a compliance statement. Similarly, an "enterprise-specific" module might include definitions of managed objects and a capability statement based on an extension. Of course, a "standard" module may not contain capability statements.
Each module is identified by an upper-case identifier. The names of all standard modules must be unique (but different versions of the same module should have the same name). Developers of enterprise modules are encouraged to choose names for their modules that will have a low probability of colliding with standard or other enterprise modules, e.g. by using the enterprise or organization name as a prefix.
Identifiers are used to identify different kinds of SMIng items by name. These names are valid in a namespace which is dependent on the SMIng item. Those items are
Each identifier starts with an upper-case or lower-case character, dependent on the kind of SMIng item, followed by zero or more letters, digits, and hyphens.
For all identifiers of a single kind of item defined in a namespace, the identifier MUST be unique and SHOULD be mnemonic. Identifiers MUST NOT exceed 64 characters in length. Furthermore, the set of all identifiers defined in all modules of a single standardization body or organization SHOULD be unique. This promotes a common language for humans to use when discussing a module.
To reference an item that is defined in the local module, its definition MUST sequentially precede the reference. Thus, there MUST NOT be any forward references, except in two cases:
To reference an item, that is defined in an external module it MUST be imported into the local module's namespace (The module's import Statement). Identifiers that are neither defined nor imported MUST NOT be visible in the local module. On the other hand, all items defined in a module are implicitly exported.
Note when identifiers from external modules are referenced, there is the possibility of name collisions. As such, if different items with the same identifier are imported or if imported identifiers collide with identifiers of locally defined items, then this ambiguity is resolved by prefixing those identifiers with the names of their modules and the namespace operator `::', i.e. `Module::item'. Of course, this notation can be used to refer to identifiers even when there is no name collision.
Note that SMIng language keywords MUST NOT be imported. The main set of keywords are SMIng statements and base types. See the `...Keyword' rules of the SMIng ABNF grammar in The SMIng ABNF grammar for a list of those keywords.
Finally, by convention, if the identifier refers to an object with a counter type (Counter32 or Counter64, derived from Unsigned32 and Unsigned64) then the identifier used for the object SHOULD denote plurality.
The layers of the object identifier tree near the root are well defined and organized by standardization bodies. The first level next to the root has three nodes:
0: ccitt
1: iso
2: joint-iso-ccitt
Note that the renaming of the Commite Consultatif International de Telegraphique et Telephonique (CCITT) to International Telecommunications Union (ITU) had no consequence on the names used in the object identifier tree.
The root of the subtree administered by the Internet Assigned Numbers Authority (IANA) for the Internet is `1.3.6.1' which is assigned with the identifier `internet'. That is, the Internet subtree of object identifiers starts with the prefix `1.3.6.1.'.
Several branches underneath this subtree are used for network management:
The `mgmt' (internet.2) subtree is used to identify "standard" information.
The `experimental' (internet.3) subtree is used to identify information being designed by working groups of the IETF or IRTF. If a module produced by a working group becomes a "standard" module then at the very beginning of its entry onto the Internet standards track, the information is moved under the mgmt subtree.
The `private' (internet.4) subtree is used to identify information defined unilaterally. The `enterprises' (private.1) subtree beneath private is used, among other things, to permit providers of networking subsystems to register models of their products.
These and some other nodes are defined in the SMIng standard module IRTF-NMRG-SMING.
Each node in the object identifier tree may be of a single kind which may represent management information or not:
Instances of managed objects are identified by appending an instance-identifier to the object's object identifier. Scalar objects and columnar objects use different ways to construct the instance-identifier.
Scalar objects have zero or one object instance. If it exists, it is identified by appending a single `0' sub-identifier to the object identifier of the scalar object.
Within tables, different instances of the same columnar object are identified by appending a sequence of one or more sub-identifiers to the object identifier of the columnar object which consists of the values of object instances that unambiguously distinguish a table row. These indexing objects can be columnar objects of the same and/or another table, but MUST NOT be scalar objects. Multiple applications of the same object in a single table indexing specification are strongly discouraged.
The base types (Base Types and Derived Types) of the indexing objects indicate how to form the instance-identifier:
Note that compact encoding can only be applied to an object having a variable-length syntax (e.g., variable-length strings, bits objects or object identifier-valued objects). Further, compact encoding can only be associated with the last object in a list of indexing objects. Finally, compact encoding may not be used on a variable-length string object if that string might have a value of zero-length.
Instances identified by use of integer-valued or enumeration-valued objects are RECOMMENDED to be numbered starting from one (i.e., not from zero).
Objects which are both specified for indexing in a row and also columnar objects of the same row are termed auxiliary objects. Auxiliary objects SHOULD be non-accessible, except in the following circumstances:
TOC |
SMIng has a minimal but complete set of base types, similar to those of many programming languages, but with some differences due to special requirements from the management information model described in The Information Model.
Additional types may be defined, derived from those base types and even from other derived types. Derived types may use subtyping to formally restrict the possible values. A set of derived types commonly used in the SNMP framework is defined in the SMIng standard module IRTF-NMRG-SMING-TYPES.
Note that types can also be restricted "inline" in object definitions (The scalar Statement, The table row's column Statement) or in refinements of compliance statements (The compliance Statement) without referring an explicitly defined type.
The different base types and its derived types allow different kinds of subtyping, namely size restrictions and range restrictions. See the following sections on base types (OctetString through Bits) for details.
The OctetString base type represents arbitrary binary or textual data. Although SMIng has a theoretical size limitation of 2^32-1 (4294967295) octets for this base type, MIB designers should realize that there may be implementation and interoperability limitations for sizes in excess of 255 octets.
Values of octet strings may be denoted as textual data enclosed in double quotes or as arbitrary binary data denoted as a `0x'-prefixed hexadecimal value of arbitrary but even length, where each pair of hexadecimal digits represents a single octet. Letters in hexadecimal values MAY be upper-case but lower-case characters are RECOMMENDED. Textual data may contain any number (possibly zero) of any 7-bit displayable ASCII characters except double quote `"', including tab characters, spaces and line terminator characters (nl or cr & nl). Textual data may span multiple lines, where each subsequent line prefix containing only white space up to the column where the first line's data starts SHOULD be skipped by parsers for a better text formatting. Note that textual data is not only used in object (default) values, but also in arguments of many SMIng statements.
When defining a type derived (directly or indirectly) from the OctetString base type, the size in octets may be restricted by appending a list of size ranges or explicit size values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A size range consists of a lower bound, two consecutive dots `..' and an upper bound. Each value can be given in decimal or `0x'-prefixed hexadecimal notation. Of course, size restricting values MUST NOT be negative. If multiple values or ranges are given, they all MUST be disjunct and SHOULD be in ascending order. If a size restriction is applied to an already size restricted octet string the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative size choices, or splitting ranges into multiple ranges with intermediate gaps.
Value Examples:
"This is a multiline textual data example." // legal "This is "illegally" quoted." // illegal quotes "But this is 'ok'." // legal apostrophe quoting "" // legal zero length 0x123 // illegal odd hex length 0x534d 496e 670a // legal octet string
Restriction Examples:
OctetString (0 | 4..255) // legal size spec OctetString (4) // legal exact size OctetString (-1 | 1) // illegal negative size OctetString (1 | 1..10) // illegal overlapping
The ObjectIdentifier base type represents any object identifier value, which is a list of up to 128 numbers, named sub-identifiers. Each sub-identifier has a value between 0 and 2^32-1 (4294967295).
Values of object identifiers may be denoted as a sequence of numerical sub-identifier values (decimal or `0x'-prefixed hexadecimal) separated by single dots and without any intermediate white space. Alternatively (and preferred in most cases), the first element may be a previously defined or imported lower-case identifier, representing a static object identifier prefix while the total number of sub-identifiers MUST NOT exceed 128 including the expanded identifier.
Object identifier derived types cannot be restricted in any way.
Value Examples:
0 // legal single subid 1.3.6.1 // legal numerical oid mib-2.1 // legal oid with identifier prefix internet.4.1.0x0627.0x01 // legal oid with hex subids iso.-1 // illegal negative subid iso.org.6 // illegal non-heading identifier
The Integer32 base type represents integer values between -2^31 (-2147483648) and 2^31-1 (2147483647).
Values of type Integer32 may be denoted as decimal or hexadecimal numbers, where only decimal numbers can be negative. Other decimal numbers than zero MUST NOT have leading zero digits. Hexadecimal numbers are prefixed by `0x' and MUST have an even number of hexadecimal digits, where letters MAY be upper-case but lower-case characters are RECOMMENDED.
When defining a type derived (directly or indirectly) from the Integer32 base type, the set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. Each value can be given in decimal or `0x'-prefixed hexadecimal notation. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps.
Value Examples:
015 // illegal leading zero -123 // legal negative value - 1 // illegal intermediate space 0xabc // illegal hexadecimal value length -0xff // illegal sign on hex value 0xf00f // legal hexadecimal value
Restriction Examples:
Integer32 (0 | 5..10) // legal range spec Integer32 (4..8 | 5..10) // illegal overlapping
The Integer64 base type represents integer values between -2^63 (-9223372036854775808) and 2^63-1 (9223372036854775807).
Values of type Integer64 may be denoted as decimal or hexadecimal numbers, where only decimal numbers can be negative. Other decimal numbers than zero MUST NOT have leading zero digits. Hexadecimal numbers are prefixed by `0x' and MUST have an even number of hexadecimal digits, where letters MAY be upper-case but lower-case characters are RECOMMENDED.
When defining a type derived (directly or indirectly) from the Integer64 base type, the set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. Each value can be given in decimal or `0x'-prefixed hexadecimal notation. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps.
The Unsigned32 base type represents positive integer values between 0 and 2^32-1 (4294967295).
Values of type Unsigned32 may be denoted as decimal or hexadecimal numbers. Other decimal numbers than zero MUST NOT have leading zero digits. Hexadecimal numbers are prefixed by `0x' and MUST have an even number of hexadecimal digits, where letters MAY be upper-case but lower-case characters are RECOMMENDED.
When defining a type derived (directly or indirectly) from the Unsigned32 base type, the set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. Each value can be given in decimal or `0x'-prefixed hexadecimal notation. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps.
The Unsigned64 base type represents positive integer values between 0 and 2^64-1 (18446744073709551615).
Values of type Unsigned64 may be denoted as decimal or hexadecimal numbers. Other decimal numbers than zero MUST NOT have leading zero digits. Hexadecimal numbers are prefixed by `0x' and MUST have an even number of hexadecimal digits, where letters MAY be upper-case but lower-case characters are RECOMMENDED.
When defining a type derived (directly or indirectly) from the Unsigned64 base type, the set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. Each value can be given in decimal or `0x'-prefixed hexadecimal notation. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps.
The Float32 base type represents floating point values of single precision as described by [11].
Values of type Float32 may be denoted as a decimal fraction with an optional exponent as known from many programming languages. See the grammar rule `floatValue' of The SMIng ABNF grammar for the detailed syntax. Special values are `snan' (signaling Not-a-Number), `qnan' (quiet Not-a-Number), `neginf' (negative infinity), and `posinf' (positive infinity). Note that -0.0 and +0.0 are different floating point values. 0.0 is equal to +0.0.
When defining a type derived (directly or indirectly) from the Float32 base type the, set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps. The special values `snan', `qnan', `neginf', and `posinf' must be explicitly listed in restrictions if they shall be included, where `snan' and `qnan' cannot be used in ranges.
Note that encoding is not subject to this specification. It has to be described by protocols that transport objects of type Float32. Note also that most floating point encodings disallow the representation of many values that can be written as decimal fractions as used in SMIng for human readability. Therefore, explicit values in floating point type restrictions should be handled with care.
Value Examples:
00.1 // illegal leading zero 3.1415 // legal value -2.5E+3 // legal negative exponential value
Restriction Examples:
Float32 (-1.0..1.0) // legal range spec Float32 (1 | 3.3 | 5) // legal, probably unrepresentable 3.3 Float32 (-10.0..10.0 | 0) // illegal overlapping
The Float64 base type represents floating point values of double precision as described by [11].
Values of type Float64 may be denoted as a decimal fraction with an optional exponent as known from many programming languages. See the grammar rule `floatValue' of The SMIng ABNF grammar for the detailed syntax. Special values are `snan' (signaling Not-a-Number), `qnan' (quiet Not-a-Number), `neginf' (negative infinity), and `posinf' (positive infinity). Note that -0.0 and +0.0 are different floating point values. 0.0 is equal to +0.0.
When defining a type derived (directly or indirectly) from the Float64 base type the, set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps. The special values `snan', `qnan', `neginf', and `posinf' must be explicitly listed in restrictions if they shall be included, where `snan' and `qnan' cannot be used in ranges. If 0.0 is included, -0.0 will also be.
Note that encoding is not subject to this specification. It has to be described by protocols that transport objects of type Float64. Note also that most floating point encodings disallow the representation of many values that can be written as decimal fractions as used in SMIng for human readability. Therefore, explicit values in floating point type restrictions should be handled with care.
Value Examples:
00.1 // illegal leading zero 3.1415 // legal value -2.5E+3 // legal negative exponential value
Restriction Examples:
Float64 (-1.0..1.0) // legal range spec Float64 (1 | 3.3 | 5) // legal, probably unrepresentable 3.3 Float64 (-10.0..10.0 | 0) // illegal overlapping
The Float128 base type represents floating point values of quadruple precision as described by [11].
Values of type Float128 may be denoted as a decimal fraction with an optional exponent as known from many programming languages. See the grammar rule `floatValue' of The SMIng ABNF grammar for the detailed syntax. Special values are `snan' (signaling Not-a-Number), `qnan' (quiet Not-a-Number), `neginf' (negative infinity), and `posinf' (positive infinity). Note that -0.0 and +0.0 are different floating point values. 0.0 is equal to +0.0.
When defining a type derived (directly or indirectly) from the Float128 base type the, set of possible values may be restricted by appending a list of ranges or explicit values, separated by pipe `|' characters and the whole list enclosed in parenthesis. A range consists of a lower bound, two consecutive dots `..' and an upper bound. If multiple values or ranges are given they all MUST be disjunct and SHOULD be in ascending order. If a value restriction is applied to an already restricted type the new restriction MUST be more limiting, that is raising the lower bounds, reducing the upper bounds, reducing the alternative choices, or splitting ranges into multiple ranges with intermediate gaps. The special values `snan', `qnan', `neginf', and `posinf' must be explicitly listed in restrictions if they shall be included, where `snan' and `qnan' cannot be used in ranges. If 0.0 is included, -0.0 will also be.
Note that encoding is not subject to this specification. It has to be described by protocols that transport objects of type Float128. Note also that most floating point encodings disallow the representation of many values that can be written as decimal fractions as used in SMIng for human readability. Therefore, explicit values in floating point type restrictions should be handled with care.
Value Examples:
00.1 // illegal leading zero 3.1415 // legal value -2.5E+3 // legal negative exponential value
Restriction Examples:
Float128 (-1.0..1.0) // legal range spec Float128 (1 | 3.3 | 5) // legal, probably unrepresentable 3.3 Float128 (-10.0..10.0 | 0) // illegal overlapping
The Enumeration base type represents values from a set of integers in the range between -2^31 (-2147483648) and 2^31-1 (2147483647), where each value has an assigned name. The list of those named numbers has to be comma-separated, enclosed in parenthesis and appended to the `Enumeration' keyword. Each named number is denoted by its lower-case identifier followed by the assigned integer value, denoted as a decimal or `0x'-prefixed hexadecimal number, enclosed in parenthesis. Every name and every number in an enumeration type MUST be unique. It is RECOMMENDED that values start at 1 and be numbered contiguously.
Values of enumeration types may be denoted as decimal or `0x'-prefixed hexadecimal numbers or preferably as their assigned names.
When defining a type derived (directly or indirectly) from an enumeration type the set, of named numbers may be restricted by removing one or more named numbers. But no named numbers may be added or changed regarding its name, value, or both.
Type and Value Examples:
Enumeration (up(1), down(2), testing(3)) 0 // illegal, value 0 out of range up // legal value given by name 2 // legal value given by number
The Bits base type represents bit sets. That is, a Bits value is a set of flags identified by small integer numbers starting at 0. Each number has an assigned name. The list of those named numbers has to be comma-separated, enclosed in parenthesis and appended to the `Bits' keyword. Each named number is denoted by its lower-case identifier followed by the assigned integer value, denoted as a decimal or `0x'-prefixed hexadecimal number, enclosed in parenthesis. Every name and every number in a bits type MUST be unique. It is RECOMMENDED that numbers start at 0 and be numbered contiguously.
Values of bits types may be denoted as a comma-separated list of decimal or `0x'-prefixed hexadecimal numbers or preferably their assigned names enclosed in parenthesis. There MUST NOT be any element (by name or number) listed more than once. It is RECOMMENDED to list elements in ascending order, although the order is semantically irrelevant.
When defining a type derived (directly or indirectly) from a bits type, the set of named numbers may be restricted by removing one or more named numbers. But no named numbers may be added or changed regarding its name, value, or both.
Type and Value Examples:
Bits (readable(0), writeable(1), executable(2)) () // legal empty value (readable, writeable, 2) // legal value (0, readable, executable) // illegal, readable(0) appears twice (writeable, 4) // illegal, element 4 out of range
Some SMIng definitions, namely scalar and columnar object definitions and type definitions, allow the specification of a format to be used, when a value of that object or an object of that type is displayed. Format specifications are represented as textual data.
When the object or type has an underlying base type of Integer32, Integer64, Unsigned32, or Unsigned64, the format consists of an integer-format specification, containing two parts. The first part is a single character suggesting a display format, either: `x' for hexadecimal, or `d' for decimal, or `o' for octal, or `b' for binary. For all types, when rendering the value, leading zeros are omitted, and for negative values, a minus sign is rendered immediately before the digits. The second part is always omitted for `x', `o' and `b', and need not be present for `d'. If present, the second part starts with a hyphen and is followed by a decimal number, which defines the implied decimal point when rendering the value. For example `d-2' suggests that a value of 1234 be rendered as `12.34'.
When the object or type has an underlying base type of OctetString, the hint consists of one or more octet-format specifications. Each specification consists of five parts, with each part using and removing zero or more of the next octets from the value and producing the next zero or more characters to be displayed. The octets within the value are processed in order of significance, most significant first.
The five parts of a octet-format specification are:
Output of a display separator character or a repeat terminator character is suppressed if it would occur as the last character of the display.
If the octets of the value are exhausted before all the octet format specification have been used, then the excess specifications are ignored. If additional octets remain in the value after interpreting all the octet format specifications, then the last octet format specification is re-interpreted to process the additional octets, until no octets remain in the value.
Note that for some types (e.g. ObjectIdentifier) no format specifications are defined and SHOULD be omitted. Implementations MUST ignore format specifications they cannot interpret. Also note that the SMIng grammar (The SMIng ABNF grammar) does not specify the syntax of format specifications.
TOC |
The topmost container of SMIng information is a file. An SMIng file may contain zero, one or more modules. It is RECOMMENDED to separate modules into files named by their modules, where possible. Though, for dedicated purposes it may be reasonable to collect several modules in a single file.
The top level SMIng construct is the `module' statement (The module Statement) that defines a single MIB module. A module contains a sequence of sections in an obligatory order with different kinds of definitions. Whether these sections contain statements or remain empty mainly depends on the purpose of the module (see The Information Model).
Comments can be included at any position in an SMIng file, except in between the characters of a single token like those of a quoted strings. However, it is RECOMMENDED that all substantive descriptions be placed within an appropriate description clause.
Comments commence with a pair of adjacent slashes `//' and end at the end of the line.
SMIng has a very small set of basic grammar rules based on the concept of statements. Each statement starts with a lower-case keyword identifying the statement followed by a number (possibly zero) of arguments. An argument may be quoted text, an identifier, a value of any base type, a list of identifiers enclosed in parenthesis `( )' or a statement block enclosed in curly braces `{ }'. Since statement blocks are valid arguments, it is possible to nest statement sequences. Each statement is terminated by a semicolon `;'.
The core set of statements may be extended using the SMIng `extension' statement. See The extension Statement and SMIng Language Extensibility for details.
At places where a statement is expected, but an unknown lower-case word is read, those statements MUST be skipped up to the proper semicolon, including nested statement blocks.
TOC |
The `module' statement is used as a container of all definitions of a single SMIng MIB module. It gets three arguments: an upper-case module name, a lower-case module identifier associated with the module's object identifier and a statement block that contains mandatory and optional statements and sections of statements in an obligatory order:
module <MODULE-NAME> <moduleIdentifier> { <optional import statements> <oid statement> <organization statement> <contact statement> <description statement> <optional reference statement> <at least one revision statement> <optional extension statements> <optional typedef statements> <optional node/scalar/table statements> <optional notification statements> <optional group statements> <optional compliance statements> };
The optional `import' statements are followed by the mandatory `oid', `organization', `contact', and `description' statements and the optional `reference' statement, which in turn are followed by the mandatory `revision' statements. This part defines the module's meta information while the following sections contain its main definitions.
See the `moduleStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `module' statement.
The optional module's `import' statement is used to import descriptors from external modules into the local module's namespace. It gets two arguments: the name of the external module and a comma-separated list of one or more identifiers to be imported enclosed in parenthesis.
Multiple `import' statements for the same module but with disjunct lists of identifiers are allowed, though NOT RECOMMENDED. Anyhow, the same identifier from the same module MUST NOT be imported multiple times. To import identifiers with the same name from different modules might be necessary and is allowed. To distinguish them in the local module, they have to be referred by qualified names. It is NOT RECOMMENDED to import identifiers not used in the local module.
See the `importStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `import' statement.
The module's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to the local module.
The module's `organization' statement, which must be present, gets one argument which is used to specify a textual description of the organization(s) under whose auspices this module was developed.
The module's `contact' statement, which must be present, gets one argument which is used to specify the name, postal address, telephone number, and electronic mail address of the person to whom technical queries concerning this revision of this module should be sent.
The module's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the contents of this module.
The module's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related management information, or some other document which provides additional information relevant to this module.
The module's `revision' statement is repeatedly used to specify the editorial revisions of the module, including the initial revision. It gets one argument which is a statement block that holds detailed information in an obligatory order. A module MUST have at least one initial `revision' statement. For every editorial change, a new one MUST be added in front of the revisions sequence, so that all revisions are in reverse chronological order.
See the `revisionStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `revision' statement.
The revision's `date' statement, which must be present, gets one argument which is used to specify the date and time of the revision in the format `YYYY-MM-DD HH:MM' or `YYYY-MM-DD' which implies the time `00:00'. The time is always given in UTC.
See the `date' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the revision's `date' statement.
The revision's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the revision.
Consider how a skeletal MIB module might be constructed: e.g.,
module FIZBIN-MIB fizbin { import IRTF-NMRG-SMING (experimental); oid experimental.xx; // contact IANA for actual number organization "IETF SNMPv2 Working Group, IRTF Network Management Research Group (NMRG)"; contact " Juergen Schoenwaelder Postal: TU Braunschweig Bueltenweg 74/75 38106 Braunschweig DE Phone: +49 531 391-3283 EMail: schoenw@ibr.cs.tu-bs.de"; description "The MIB module for entities implementing the xxxx protocol."; reference "RFC 2578, Section 5.7."; revision { date "1999-04-19"; description "Conversion from SMIv2 to SMIng."; }; revision { date "1995-05-24 18:11"; description "Revision for RFC 1902."; }; revision { date "1992-10-07 04:33"; description "The initial version of this MIB module, published in RFC 1442."; }; // ... further definitions ... }; // end of module FIZBIN-MIB.
TOC |
The `extension' statement is used to define new statements to be used in the local module or in external modules. It gets two arguments: a lower-case extension statement identifier and a statement block that holds detailed extension information in an obligatory order.
Extension statement identifiers SHOULD NOT contain any upper-case characters or hyphens.
Note that the SMIng extension feature does not allow to formally specify the context, argument syntax and semantics of an extension. Its only purpose is to declare the existence of an extension and to allow a unique reference to an extension. See SMIng Language Extensibility for detailed information on extensions and IRTF-NMRG-SMING-EXTENSIONS for a common example, the `agentcaps' extension.
See the `extensionStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `extension' statement.
The extension's `status' statement, which need not be present, gets one argument which is used to specify whether this extension definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
If the `status' statement is omitted, the status value `current' is implied.
The extension's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the extension statement.
It is RECOMMENDED to include information on the extension's context, its syntax (preferably in ABNF notation), and its semantics.
The extension's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related extension definitions, or some other document which provides additional information relevant to this extension.
TOC |
The `typedef' statement is used to define new data types to be used in the local module or in external modules. It gets two arguments: an upper-case type identifier and a statement block that holds detailed type information in an obligatory order.
Type identifiers SHOULD NOT consist of all upper-case characters and SHOULD NOT contain hyphens.
See the `typedefStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `typedef' statement.
The typedef's `type' statement, which must be present, gets one argument which is used to specify the type from which this type is derived. Optionally, type restrictions may be applied to the new type by appending subtyping information according to the rules of the base type. See Base Types and Derived Types for SMIng base types and their type restrictions.
The typedef's `default' statement, which need not be present, gets one argument which is used to specify an acceptable default value for objects of this type. A default value may be used at the discretion of an agent when an object instance is created. That is, the value is a "hint" to implementors.
The value of the `default' statement must, of course, correspond to the (probably restricted) type specified in the typedef's `type' statement.
The default value of a type may be overwritten by a default value of an object of this type.
Note that for some types, default values make no sense, e.g. IRTF-NMRG-SMING-TYPES::Counter32.
The typedef's `format' statement, which need not be present, gets one argument which is used to give a hint as to how the value of an instance of an object of this type might be displayed. See Display Formats for a description of format specifications.
The format specification of a type may be overwritten by a format specification of an object of this type.
The typedef's `units' statement, which need not be present, gets one argument which is used to specify a textual definition of the units associated with objects of this type.
The units specification of a type may be overwritten by a units specification of an object of this type.
The units specification has to be appropriate for values displayed according to the typedef's format specification, if present. E.g., if the type defines frequency values of type Unsigned64 measured in thousands of Hertz, the format specification should be `d-3' and the units specification should be `Hertz' or `Hz'. If the format specification would be omitted, the units specification should be `Milli-Hertz' or `mHz'. MIB Authors should pay attention to keep format and units specifications of type and object definitions synced. Application implementors MUST NOT implement units specifications without implementing format specifications.
The typedef's `status' statement, which need not be present, gets one argument which is used to specify whether this type definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
Derived types SHOULD NOT be defined as `current' if their underlying type is `deprecated' or `obsolete'. Similarly, they SHOULD NOT be defined as `deprecated' if their underlying type is `obsolete'. Nevertheless, subsequent revisions of the underlying type cannot be avoided, but SHOULD be taken into account in subsequent revisions of the local module.
If the `status' statement is omitted, the status value `current' is implied.
The typedef's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the newly defined type.
It is RECOMMENDED to include all semantic definitions necessary for implementation, and to embody any information which would otherwise be communicated in any commentary annotations associated with this type definition.
The typedef's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related type definitions, or some other document which provides additional information relevant to this type definition.
typedef RptrOperStatus { type Enumeration (other(1), ok(2), rptrFailure(3), groupFailure(4), portFailure(5), generalFailure(6)); default other; // undefined by default. status deprecated; description "A type to indicate the operational state of a repeater."; reference "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."; }; typedef DateAndTime { type OctetString (8 | 11); format "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"; status current; // could be omitted description "A date-time specification. ... Note that if only local time is known, then timezone information (fields 8-10) is not present."; reference "RFC 2579, SNMPv2-TC.DateAndTime."; }; typedef Frequency { type Unsigned64; format "d-3" units "Hertz"; description "A wide-range frequency specification measured in thousands of Hertz."; };
TOC |
The `node' statement is used to name and describe a node in the object identifier tree, without associating object information with this node. This may be useful to group definitions in a subtree of related management information, or to uniquely define an identity of arbitrary kind to be referenced in objects of type ObjectIdentifier. The `node' statement gets two arguments: a lower-case node identifier and a statement block that holds detailed node information in an obligatory order.
See the `nodeStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `node' statement.
The node's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this node.
The node's `status' statement, which need not be present, gets one argument which is used to specify whether this node definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
If the `status' statement is omitted, the status value `current' is implied.
The node's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this node.
It is RECOMMENDED to include all semantics and purposes of this node.
The node's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related nodes, or some other document which provides additional information relevant to this node.
node iso { oid 1; }; node org { oid iso.3; }; node dod { oid org.6; }; node internet { oid dod.1; }; node zeroDotZero { oid 0.0; description "A value used for null identifiers."; reference "RFC 2578, 2. Definitions."; };
TOC |
The `scalar' statement is used to define a scalar managed object. The `scalar' statement gets two arguments: a lower-case scalar identifier and a statement block that holds detailed object information in an obligatory order.
See the `scalarStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `scalar' statement.
The scalar's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this scalar object.
The scalar's `type' statement, which must be present, gets one argument which is used to specify the data type of this scalar object. Optionally, type restrictions may be applied to the type by appending subtyping information according to the rules of the base type. See Base Types and Derived Types for SMIng base types and their type restrictions.
The scalar's `access' statement, which must be present, gets one argument which is used to specify whether it makes sense to read and/or write an instance of the object, or to include its value in a notification. This is the maximal level of access for the object. This maximal level of access is independent of any administrative authorization policy.
The value `readwrite' indicates that read and write access makes sense. The value `readonly' indicates that read access makes sense, but write access is never possible. The value `notifyonly' indicates an object which is accessible only via a notification.
These values are ordered, from least to greatest access level: `notifyonly', `readonly', `readwrite'.
The scalar's `default' statement, which need not be present, gets one argument which is used to specify an acceptable default value for this scalar object. A default value may be used at the discretion of an agent when an object instance is created. That is, the value is a "hint" to implementors.
The value of the `default' statement must, of course, correspond to the (probably restricted) type specified in the scalar's `type' statement.
The scalar's default value overrides the default value of the underlying type definition, if both are present.
Note that for objects of some types, default values make no sense, e.g. IRTF-NMRG-SMING-TYPES::Counter32.
The scalar's `format' statement, which need not be present, gets one argument which is used to give a hint as to how the value of an instance of this object might be displayed. See Display Formats for a description of format specifications.
The scalar's format specification overrides the format specification of the underlying type definition if both are present.
The scalar's `units' statement, which need not be present, gets one argument which is used to specify a textual definition of the units associated with this scalar object.
The scalar's units specification overrides the units specification of the underlying type definition if both are present.
The units specification has to be appropriate for values displayed according to the scalar's format specification if present. E.g., if the scalar object represents a frequency value of type Unsigned64 measured in thousands of Hertz, the format specification should be `d-3' and the units specification should be `Hertz' or `Hz'. If the format specification would be omitted, the units specification should be `Milli-Hertz' or `mHz'. MIB Authors should pay attention to keep format and units specifications of type and object definitions synced. Application implementors MUST NOT implement units specifications without implementing format specifications.
The scalar's `status' statement, which need not be present, gets one argument which is used to specify whether this scalar object definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
Scalar objects SHOULD NOT be defined as `current' if their type is `deprecated' or `obsolete'. Similarly, they SHOULD NOT be defined as `deprecated' if their type is `obsolete'. Nevertheless, subsequent revisions of used type definition cannot be avoided, but SHOULD be taken into account in subsequent revisions of the local module.
If the `status' statement is omitted the status value `current' is implied.
The scalar's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this scalar object.
It is RECOMMENDED to include all semantic definitions necessary for the implementation of this scalar object.
The scalar's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related scalar objects, or some other document which provides additional information relevant to this scalar object.
scalar dialCtlTrapEnable { oid dialCtlConfiguration.2; type Enumeration (enabled(1), disabled(2)); access readwrite; default disabled; description "This object indicates whether dialCtlPeerCallInformation and dialCtlPeerCallSetup traps should be generated for all peers. If the value of this object is enabled(1), traps will be generated for all peers. If the value of this object is disabled(2), traps will be generated only for peers having dialCtlPeerCfgTrapEnable set to enabled(1)."; };
TOC |
The `table' statement is used to define the root node of a table. The `table' statement gets two arguments: a lower-case table identifier and a statement block that holds detailed table information in an obligatory order.
See the `tableStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `table' statement.
The table's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this table node.
The table's `status' statement, which need not be present, gets one argument which is used to specify whether this table definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
If the `status' statement is omitted the status value `current' is implied.
The table's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this table.
It is RECOMMENDED to include all semantic definitions necessary for the implementation of this table.
The table's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related tables, or some other document which provides additional information relevant to this table.
The table's `row' statement, which must be present, gets two arguments: a lower-case row identifier and a statement block that holds detailed row information in an obligatory order.
See the `rowStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `row' statement.
The row's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this table row.
SMIng offers five methods to supply table indexing information: ordinary tables, table augmentations, sparse table augmentations, table expansions, and reordered tables use different statements to denote their indexing information. Each table row definition must contain exactly one of the following indexing statements.
The row's `index' statement, which is used to supply table indexing information of base table rows, gets at least one argument that specifies a comma-separated list of object identifiers, that are used for table indexing, enclosed in parenthesis.
Under some circumstances, an optional `implied' keyword may be added in front of the list to indicate a compact encoding of the last object in the list. See Scalar and Columnar Objects' Instances for details.
The row's `augments' statement, which is used to supply table indexing information of table rows that augment a base table row, gets one argument that specifies the identifier of the table row to be augmented. Note that a row augmentation cannot itself be augmented. Anyhow, a base row may be augmented by multiple row augmentations.
A row augmentation makes instances of subordinate columnar objects identified according to the index specification of the base row corresponding to the row named in the `augments' statement. Further, instances of subordinate columnar objects of a row augmentation exist according to the same semantics as instances of subordinate columnar objects of the base row being augmented. As such, note that creation of a base row implies the correspondent creation of any row augmentations. Row augmentations MUST NOT be used in row creation and deletion operations.
The row's `sparse' statement, which is used to supply table indexing information of table rows that sparsely augment a base table row, gets one argument that specifies the identifier of the table row to be sparsely augmented. Note that a sparse row augmentation cannot itself be augmented. Anyhow, a base row may be augmented by multiple row augmentations, sparsely or not.
A sparse row augmentation makes instances of subordinate columnar objects identified, if present, according to the index specification of the base row corresponding to the row named in the `sparse' statement. Further, instances of subordinate columnar objects of a sparse row augmentation exist according to the semantics as instances of subordinate columnar objects of the base row and the (non-formal) rules that confine the sparse relationship. As such, note that creation of a base row implies the correspondent creation of any sparse row augmentations if the sparse relationship is matched. Sparse row augmentations MUST NOT be used in row creation and deletion operations.
The row's `reorders' statement is used to supply table indexing information of table rows, that contain exactly the same index objects of a base table row, except in another order. It gets at least two arguments. The first one specifies the identifier of the base table row. The second one specifies a comma-separated list of exactly those object identifiers of the base row's `index' statement, but in the order to be used in this table. Note that a reordered table cannot itself be reordered. Anyhow, a base row may be used for multiple reordered tables.
Under some circumstances, an optional `implied' keyword may be added in front of the list to indicate a compact encoding of the last object in the list. See Scalar and Columnar Objects' Instances for details.
Instances of subordinate columnar objects of a reordered table exist according to the same semantics as instances of subordinate columnar objects of the base row. As such, note that creation of a base row implies the correspondent creation of any related reordered table. Rows or reordered tables MUST NOT be used in row creation and deletion operations.
The row's `expands' statement is used to supply table indexing information of table row expansions. Table row expansions use exactly the same index objects of another row together with additional indexing objects. Thus, the `expands' statement gets at least two arguments. The first one specifies the identifier of the related table row. The second one specifies a comma-separated list of the additional object identifiers used for indexing. Note that an expanded table may itself be expanded, and related rows may be used for multiple table expansions.
Under some circumstances, an optional `implied' keyword may be added in front of the list to indicate a compact encoding of the last object in the list. See Scalar and Columnar Objects' Instances for details.
The row's `create' statement, which need not be present, gets one argument which specifies whether the table allows row creation and deletion and which columns are required to be supplied in row creation operations.
Only if the `create' statement is present, row creation and deletion is possible. A comma-separated list of column identifiers enclosed in parenthesis may be supplied as an optional argument. This denotes, that the named columns must be supplied in row creation operations. If this list is not present, there are no explicitly required columns to be supplied in row creation operations.
The row's `status' statement, which need not be present, gets one argument which is used to specify whether this row definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
If the `status' statement is omitted the status value `current' is implied.
The row's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this table row.
It is RECOMMENDED to include all semantic definitions necessary for the implementation of this table row. Especially, if the row's indexing statement contains objects that are not columnar objects of the row, it SHOULD be described how these objects are used in uniquely identifying instances of the row's columnar objects.
The row's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related table rows, or some other document which provides additional information relevant to this table row.
The row's `column' statement is used to define a columnar managed object. The `column' statement gets two arguments: a lower-case column identifier and a statement block that holds detailed object information in an obligatory order.
See the `columnStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `column' statement.
The column's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this columnar object.
The column's `type' statement, which must be present, gets at least one argument which is used to specify the data type of this columnar object. Optionally, type restrictions may be applied to the type by appending subtyping information according to the rules of the base type. See Base Types and Derived Types for SMIng base types and their type restrictions.
The column's `access' statement, which must be present, gets one argument which is used to specify whether it makes sense to read and/or write an instance of the object, or to include its value in a notification. This is the maximal level of access for the object. This maximal level of access is independent of any administrative authorization policy.
The value `readwrite' indicates that read and write access makes sense. The value `readonly' indicates that read access makes sense, but write access is never possible. The value `noaccess' indicates an auxiliary object (see Scalar and Columnar Objects' Instances). The value `notifyonly' indicates an object which is accessible only via a notification.
These values are ordered, from least to greatest access level: `noaccess', `notifyonly', `readonly', `readwrite'.
The column's `default' statement, which need not be present, gets one argument which is used to specify an acceptable default value for this columnar object. A default value may be used at the discretion of an agent when an object instance is created. That is, the value is a "hint" to implementors.
The value of the `default' statement must, of course, correspond to the (probably restricted) type specified in the column's `type' statement.
The column's default value overrides the default value of the underlying type definition if both are present.
Note that for objects of some types, default values make no sense, e.g. IRTF-NMRG-SMING-TYPES::Counter32.
The column's `format' statement, which need not be present, gets one argument which is used to give a hint as to how the value of an instance of this object might be displayed. See Display Formats for a description of format specifications.
The column's format specification overrides the format specification of the underlying type definition if both are present.
The column's `units' statement, which need not be present, gets one argument which is used to specify a textual definition of the units associated with this columnar object.
The column's units specification overrides the units specification of the underlying type definition if both are present.
The units specification has to be appropriate for values displayed according to the column's format specification if present. E.g., if the columnar object represents a frequency value of type Unsigned64 measured in thousands of Hertz, the format specification should be `d-3' and the units specification should be `Hertz' or `Hz'. If the format specification would be omitted the units specification should be `Milli-Hertz' or `mHz'. MIB Authors should pay attention to keep format and units specifications of type and object definitions synced. Application implementors MUST NOT implement units specifications without implementing format specifications.
The column's `status' statement, which need not be present, gets one argument which is used to specify whether this columnar object definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
Columnar objects SHOULD NOT be defined as `current' if their type is `deprecated' or `obsolete'. Similarly, they SHOULD NOT be defined as `deprecated' if their type is `obsolete'. Nevertheless, subsequent revisions of used type definition cannot be avoided, but SHOULD be taken into account in subsequent revisions of the local module.
If the `status' statement is omitted the status value `current' is implied.
The column's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this columnar object.
It is RECOMMENDED to include all semantic definitions necessary for the implementation of this columnar object.
The column's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related columnar objects, or some other document which provides additional information relevant to this columnar object.
Consider how one might define a table and its subordinates. (This example uses the RowStatus type defined in IRTF-NMRG-SMING-TYPES.)
scalar evalSlot { oid eval.1; type Integer32 (0..2147483647); access readonly; description "The index number of the first unassigned entry in the evaluation table, or the value of zero indicating that all entries are assigned. A management station should create new entries in the evaluation table using this algorithm: first, issue a management protocol retrieval operation to determine the value of evalSlot; and, second, issue a management protocol set operation to create an instance of the evalStatus object setting its value to createAndGo(4) or createAndWait(5). If this latter operation succeeds, then the management station may continue modifying the instances corresponding to the newly created conceptual row, without fear of collision with other management stations."; }; table evalTable { oid eval.2; description "The (conceptual) evaluation table."; reference "RFC 2578, 7.11."; row evalEntry { oid evalTable.1; index (evalIndex); create (evalStatus); description "An entry (conceptual row) in the evaluation table."; column evalIndex { oid evalEntry.1; type Integer32 (1..2147483647); access noaccess; description "The auxiliary variable used for identifying instances of the columnar objects in the evaluation table."; }; column evalString { oid evalEntry.2; type DisplayString; access readwrite; description "The string to evaluate."; }; column evalValue { oid evalEntry.3; type Integer32; access readonly; default 0; description "The value when evalString was last evaluated, or zero if no such value is available."; }; column evalStatus { oid evalEntry.4; type RowStatus; access readwrite; default active; description "The status column used for creating, modifying, and deleting instances of the columnar objects in the evaluation table."; }; }; };
TOC |
The `notification' statement is used to define a notification. It gets two arguments: a lower-case notification identifier and a statement block that holds detailed information in an obligatory order.
See the `notificationStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `notification' statement.
The notification's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this notification.
The notification's `objects' statement, which need not be present, gets one argument which specifies an ordered sequence of objects by their identifiers to be emitted within this notification. The list of objects has to be comma-separated and enclosed in parenthesis.
One and only one object instance for each occurrence of each object must be present, and in the specified order, in every instance of the notification. If the same object occurs multiple times in a notification's `objects' statement, then an object instance is present for each of them. An object specified in this sequence must not have an `access' statement argument of `noaccess'.
Note that an agent is allowed, at its own discretion, to append as many additional objects as it considers useful to the end of the notification (i.e., after the objects defined by the notification's `objects' statement if present).
The notification's `status' statement, which need not be present, gets one argument which is used to specify whether this notification definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued implementation in order to foster interoperability with older/existing implementations.
If the `status' statement is omitted the status value `current' is implied.
The notification's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this notification.
It is RECOMMENDED to include all semantic definitions necessary for the implementation of this notification. In particular, it SHOULD be documented which instances of the objects mentioned in the `objects' statement should be contained within notifications of this type.
The notification's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related notifications, or some other document which provides additional information relevant to this notification.
Consider how a configuration change notification might be described:
node entityMIBTraps { oid entityMIB.2; }; node entityMIBTrapPrefix { oid entityMIBTraps.0; }; notification entConfigChange { oid entityMIBTrapPrefix.1; description "An entConfigChange trap is sent when the value of entLastChangeTime changes. It can be utilized by an NMS to trigger logical/physical entity table maintenance polls. An agent must not generate more than one entConfigChange 'trap-event' in a five second period, where a 'trap-event' is the transmission of a single trap PDU to a list of trap destinations. If additional configuration changes occur within the five second 'throttling' period then these trap-events should be suppressed by the agent. An NMS should periodically check the value of entLastChangeTime to detect any missed entConfigChange trap-events, e.g. due to throttling or transmission loss."; };
TOC |
The `group' statement is used to define a group of arbitrary nodes in the object identifier tree. It gets two arguments: a lower-case group identifier and a statement block that holds detailed group information in an obligatory order.
Note that the primary application of groups are compliance statements, although they might be referred in other formal or informal documents.
See the `groupStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `group' statement.
The group's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this group.
The group's `members' statement, which must be present, gets one argument which specifies the list of nodes by their identifiers to be contained in this group. The list of nodes has to be comma-separated and enclosed in parenthesis.
The group's `status' statement, which need not be present, gets one argument which is used to specify whether this group definition is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued use of this group.
If the `status' statement is omitted the status value `current' is implied.
The group's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this group. It is RECOMMENDED to include any relation to other groups.
The group's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related groups, or some other document which provides additional information relevant to this group.
The snmpGroup, originally defined in [13], may be described as follows:
group snmpGroup { oid snmpMIBGroups.8; objects (snmpInPkts, snmpInBadVersions, snmpInASNParseErrs, snmpSilentDrops, snmpProxyDrops, snmpEnableAuthenTraps); description "A collection of objects providing basic instrumentation and control of an SNMPv2 entity."; };
TOC |
The `compliance' statement is used to define a set of compliance requirements, named a `compliance statement'. It gets two arguments: a lower-case compliance identifier and a statement block that holds detailed compliance information in an obligatory order.
See the `complianceStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `compliance' statement.
The compliance's `oid' statement, which must be present, gets one argument which specifies the object identifier value that is assigned to this compliance statement.
The compliance's `status' statement, which need not be present, gets one argument which is used to specify whether this compliance statement is current or historic. The value `current' means that the definition is current and valid. The value `obsolete' means the definition is obsolete and should not be implemented and/or can be removed if previously implemented. While the value `deprecated' also indicates an obsolete definition, it permits new/continued use of the compliance specification.
If the `status' statement is omitted the status value `current' is implied.
The compliance's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of this compliance statement.
The compliance's `reference' statement, which need not be present, gets one argument which is used to specify a textual cross-reference to some other document, either another module which defines related compliance statements, or some other document which provides additional information relevant to this compliance statement.
The compliance's `mandatory' statement, which need not be present, gets one argument which is used to specify a comma-separated list of one or more groups (The group Statement) of objects and/or notifications enclosed in parenthesis. These groups are unconditionally mandatory for implementation.
If an agent claims compliance to a MIB module then it must implement each and every object and notification within each group listed the `mandatory' statement(s) of the compliance statement(s) of that module.
The compliance's `optional' statement, which need not be present, is repeatedly used to name each group which is conditionally mandatory for compliance to the module. It can also be used to name unconditionally optional groups. A group named in an `optional' statement MUST be absent from the correspondent `mandatory' statement. The `optional' statement gets two arguments: a lower-case group identifier and a statement block that holds detailed compliance information on that group.
Conditionally mandatory groups include those which are mandatory only if a particular protocol is implemented, or only if another group is implemented. The `description' statement specifies the conditions under which the group is conditionally mandatory.
A group which is named in neither a `mandatory' statement nor an `optional' statement, is unconditionally optional for compliance to the module.
See the `optionalStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `optional' statement.
The optional's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the conditions under which this group is conditionally mandatory or unconditionally optional.
The compliance's `refine' statement, which need not be present, is repeatedly used to specify each object for which compliance has a refined requirement with respect to the module definition. The object must be present in one of the conformance groups named in the correspondent `mandatory' or `optional' statements. The `refine' statement gets two arguments: a lower-case identifier of a scalar or columnar object and a statement block that holds detailed refinement information on that object.
See the `refineStatement' rule of the SMIng grammar (The SMIng ABNF grammar) for the formal syntax of the `refine' statement.
The refine's `type' statement, which need not be present, gets one argument that is used to provide a refined type for the correspondent object. Type restrictions may be applied by appending subtyping information according to the rules of the base type. See Base Types and Derived Types for SMIng base types and their type restrictions.
Note that if a `type' and a `writetype' statement are both present then this type only applies when instances of the correspondent object are read.
The refine's `writetype' statement, which need not be present, gets one argument that is used to provide a refined type for the correspondent object, only when instances of that object are written. Type restrictions may be applied by appending subtyping information according to the rules of the base type. See Base Types and Derived Types for SMIng base types and their type restrictions.
The refine's `access' statement, which need not be present, gets one argument that is used to specify the minimal level of access that the correspondent object must implement in the sense of its original `access' statement. Hence, the refine's `access' statement MUST NOT specify a greater level of access than is specified in the correspondent object definition.
An implementation is compliant if the level of access it provides is greater or equal to the minimal level in the refine's `access' statement and less or equal to the maximal level in the object's `access' statement.
The refine's `description' statement, which must be present, gets one argument which is used to specify a high-level textual description of the refined compliance requirement.
The compliance statement contained in the SNMPv2-MIB, converted to SMIng:
compliance snmpBasicCompliance { oid snmpMIBCompliances.2; description "The compliance statement for SNMPv2 entities which implement the SNMPv2 MIB."; mandatory (snmpGroup, snmpSetGroup, systemGroup, snmpBasicNotificationsGroup); optional snmpCommunityGroup { description "This group is mandatory for SNMPv2 entities which support community-based authentication."; }; };
TOC |
MIB modules, either SMIv1, SMIv2 or SMIng, are built on top of some core definitions. These core definitions are imported from some "well-defined" core modules. In case of SMIng, there are two core modules:
module IRTF-NMRG-SMING irtfNmrgSming { // // $RCSfile: IRTF-NMRG-SMING,v $ // $Revision: 1.9 $ // $Author: strauss $ // $Date: 1999/05/07 15:57:26 $ // oid 1.3.6.1.3.1575.1.8; // experimental.1575.1.8 organization "IRTF Network Management Research Group (NMRG), Network Management Group, TU Braunschweig"; contact " Frank Strauss Postal: TU Braunschweig Bueltenweg 74/75 38106 Braunschweig Germany Phone: +49 531 391-3283 EMail: strauss@ibr.cs.tu-bs.de http://www.ibr.cs.tu-bs.de/~strauss/sming/"; description "Core node definitions for SMIng."; revision { date "1999-05-07"; description "Initial Revision."; }; node ccitt { oid 0; }; node zeroDotZero { oid 0.0; description "A value used for null identifiers."; }; node iso { oid 1; }; node org { oid iso.3; }; node dod { oid org.6; }; node internet { oid dod.1; }; node directory { oid internet.1; }; node mgmt { oid internet.2; }; node mib-2 { oid mgmt.1; }; node transmission { oid mib-2.10; }; node experimental { oid internet.3; }; node private { oid internet.4; }; node enterprises { oid private.1; }; node security { oid internet.5; }; node snmpV2 { oid internet.6; }; node snmpDomains { oid snmpV2.1; }; node snmpProxys { oid snmpV2.2; }; node snmpModules { oid snmpV2.3; }; node joint-iso-ccitt { oid 2; }; };
module IRTF-NMRG-SMING-TYPES irtfNmrgSmingTypes { // // $RCSfile: IRTF-NMRG-SMING-TYPES,v $ // $Revision: 1.14 $ // $Author: strauss $ // $Date: 1999/05/07 15:57:28 $ // oid 1.3.6.1.3.1575.1.9; // experimental.1575.1.9 organization "IRTF Network Management Research Group (NMRG), Network Management Group, TU Braunschweig"; contact " Frank Strauss Postal: TU Braunschweig Bueltenweg 74/75 38106 Braunschweig Germany Phone: +49 531 391-3283 EMail: strauss@ibr.cs.tu-bs.de http://www.ibr.cs.tu-bs.de/~strauss/sming/"; description "Core type definitions for SMIng."; revision { date "1999-05-07"; description "Initial Revision."; }; typedef Gauge32 { type Unsigned32; description "The Gauge32 type represents a non-negative integer, which may increase or decrease, but shall never exceed a maximum value, nor fall below a minimum value. The maximum value can not be greater than 2^32-1 (4294967295 decimal), and the minimum value can not be smaller than 0. The value of a Gauge32 has its maximum value whenever the information being modeled is greater than or equal to its maximum value, and has its minimum value whenever the information being modeled is smaller than or equal to its minimum value. If the information being modeled subsequently decreases below (increases above) the maximum (minimum) value, the Gauge32 also decreases (increases). (Note that despite of the use of the term `latched' in the original definition of this type, it does not become `stuck' at its maximum or minimum value.)"; reference "RFC 2578, Sections 2. and 7.1.7."; }; typedef Counter32 { type Unsigned32; description "The Counter32 type represents a non-negative integer which monotonically increases until it reaches a maximum value of 2^32-1 (4294967295 decimal), when it wraps around and starts increasing again from zero. Counters have no defined `initial' value, and thus, a single value of a Counter has (in general) no information content. Discontinuities in the monotonically increasing value normally occur at re-initialization of the management system, and at other times as specified in the description of an object using this type. If such other times can occur, for example, the creation of an object instance at times other than re-initialization, then a corresponding object should be defined, with an appropriate type, to indicate the last discontinuity. Examples of appropriate types include: TimeStamp, DateAndTime or TimeTicks (other types defined in this module). The value of the access statement for objects with a type value of Counter32 should be either `readonly' or `notifyonly'. A default statement should not be used for objects with a type value of Counter32."; reference "RFC 2578, Sections 2. and 7.1.6."; }; typedef Gauge64 { type Unsigned64; description "The Gauge64 type represents a non-negative integer, which may increase or decrease, but shall never exceed a maximum value, nor fall below a minimum value. The maximum value can not be greater than 2^64-1 (18446744073709551615), and the minimum value can not be smaller than 0. The value of a Gauge64 has its maximum value whenever the information being modeled is greater than or equal to its maximum value, and has its minimum value whenever the information being modeled is smaller than or equal to its minimum value. If the information being modeled subsequently decreases below (increases above) the maximum (minimum) value, the Gauge64 also decreases (increases). (Note that despite of the use of the term `latched' in the original definition of this type, it does not become `stuck' at its maximum or minimum value.)"; }; typedef Counter64 { type Unsigned64; description "The Counter64 type represents a non-negative integer which monotonically increases until it reaches a maximum value of 2^64-1 (18446744073709551615), when it wraps around and starts increasing again from zero. Counters have no defined `initial' value, and thus, a single value of a Counter has (in general) no information content. Discontinuities in the monotonically increasing value normally occur at re-initialization of the management system, and at other times as specified in the description of an object using this type. If such other times can occur, for example, the creation of an object instance at times other than re-initialization, then a corresponding object should be defined, with an appropriate type, to indicate the last discontinuity. Examples of appropriate types include: TimeStamp, DateAndTime or TimeTicks (other types defined in this module). The value of the access statement for objects with a type value of Counter64 should be either `readonly' or `notifyonly'. A default statement should not be used for objects with a type value of Counter64."; reference "RFC 2578, Sections 2. and 7.1.10."; }; typedef Opaque { type OctetString; description "The Opaque type is provided solely for backward-compatibility, and shall not be used for newly-defined object types. The Opaque type supports the capability to pass arbitrary ASN.1 syntax. A value is encoded using the ASN.1 Basic Encoding Rules into a string of octets. This, in turn, is encoded as an OctetString, in effect `double-wrapping' the original ASN.1 value. Note that a conforming implementation need only be able to accept and recognize opaquely-encoded data. It need not be able to unwrap the data and then interpret its contents. A requirement on `standard' MIB modules is that no object may have a type value of Opaque."; reference "RFC 2578, Sections 2. and 7.1.9."; }; typedef IpAddress { type OctetString (4); status deprecated; description "******* THIS TYPE DEFINITION IS DEPRECATED ******* The IpAddress type represents a 32-bit internet IPv4 address. It is represented as an OctetString of length 4, in network byte-order. Note that the IpAddress type is present for historical reasons. IPv4 and IPv6 addresses should be represented using the IpAddr type. Generic Network addresses should be represented using a pair of TDomain and TAddress types (all defined in this module)."; reference "RFC 2578, Sections 2. and 7.1.5."; }; typedef TimeTicks { type Unsigned32; description "The TimeTicks type represents a non-negative integer which represents the time, modulo 2^32 (4294967296 decimal), in hundredths of a second between two epochs. When objects are defined which use this type, the description of the object identifies both of the reference epochs. For example, the TimeStamp type (defined in this module) is based on the TimeTicks type. With a TimeStamp, the first reference epoch is defined as the time when SNMPv2-MIB::sysUpTime was zero, and the second reference epoch is defined as the current value of sysUpTime. The TimeTicks type should not be sub-typed."; reference "RFC 2578, Sections 2. and 7.1.8."; }; // // The following type definitions are plain // conversions of the textual conventions from // the SNMPv2-TC module (RFC 2579). // typedef DisplayString { type OctetString (0..255); format "255a"; description "Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length."; }; typedef PhysAddress { type OctetString; format "1x:"; description "Represents media- or physical-level addresses."; }; typedef MacAddress { type OctetString (6); format "1x:"; description "Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first."; }; typedef TruthValue { type Enumeration (true(1), false(2)); description "Represents a boolean value."; }; typedef TestAndIncr { type Integer32 (0..2147483647); description "Represents integer-valued information used for atomic operations. When the management protocol is used to specify that an object instance having this syntax is to be modified, the new value supplied via the management protocol must precisely match the value presently held by the instance. If not, the management protocol set operation fails with an error of `inconsistentValue'. Otherwise, if the current value is the maximum value of 2^31-1 (2147483647 decimal), then the value held by the instance is wrapped to zero; otherwise, the value held by the instance is incremented by one. (Note that regardless of whether the management protocol set operation succeeds, the variable- binding in the request and response PDUs are identical.) The value of the ACCESS clause for objects having this syntax is either `read-write' or `read-create'. When an instance of a columnar object having this syntax is created, any value may be supplied via the management protocol. When the network management portion of the system is re- initialized, the value of every object instance having this syntax must either be incremented from its value prior to the re-initialization, or (if the value prior to the re- initialization is unknown) be set to a pseudo-randomly generated value."; }; typedef AutonomousType { type ObjectIdentifier; description "Represents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware."; }; typedef InstancePointer { type ObjectIdentifier; status obsolete; description "A pointer to either a specific instance of a MIB object or a conceptual row of a MIB table in the managed device. In the latter case, by convention, it is the name of the particular instance of the first accessible columnar object in the conceptual row. The two uses of this textual convention are replaced by VariablePointer and RowPointer, respectively."; }; typedef VariablePointer { type ObjectIdentifier; description "A pointer to a specific object instance. For example, sysContact.0 or ifInOctets.3."; }; typedef RowPointer { type ObjectIdentifier; description "Represents a pointer to a conceptual row. The value is the name of the instance of the first accessible columnar object in the conceptual row. For example, ifIndex.3 would point to the 3rd row in the ifTable (note that if ifIndex were not-accessible, then ifDescr.3 would be used instead)."; }; typedef RowStatus { type Enumeration (active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)); description "The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of [2].) The status column has six defined values: - `active', which indicates that the conceptual row is available for use by the managed device; - `notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device (see NOTE below); - `notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device; - `createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device); and, - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Whereas five of the six values (all except `notReady') may be specified in a management protocol set operation, only three values will be returned in response to a management protocol retrieval operation: `notReady', `notInService' or `active'. That is, when queried, an existing conceptual row has only three states: it is either available for use by the managed device (the status column has value `active'); it is not available for use by the managed device, though the agent has sufficient information to make it so (the status column has value `notInService'); or, it is not available for use by the managed device, and an attempt to make it so would fail because the agent has insufficient information (the state column has value `notReady'). NOTE WELL This textual convention may be used for a MIB table, irrespective of whether the values of that table's conceptual rows are able to be modified while it is active, or whether its conceptual rows must be taken out of service in order to be modified. That is, it is the responsibility of the DESCRIPTION clause of the status column to specify whether the status column must not be `active' in order for the value of some other column of the same conceptual row to be modified. If such a specification is made, affected columns may be changed by an SNMP set PDU if the RowStatus would not be equal to `active' either immediately before or after processing the PDU. In other words, if the PDU also contained a varbind that would change the RowStatus value, the column in question may be changed if the RowStatus was not equal to `active' as the PDU was received, or if the varbind sets the status to a value other than 'active'. Also note that whenever any elements of a row exist, the RowStatus column must also exist. To summarize the effect of having a conceptual row with a status column having a SYNTAX clause value of RowStatus, consider the following state diagram: STATE +--------------+-----------+-------------+------------- | A | B | C | D | |status col.|status column| |status column | is | is |status column ACTION |does not exist| notReady | notInService| is active --------------+--------------+-----------+-------------+------------- set status |noError ->D|inconsist- |inconsistent-|inconsistent- column to | or | entValue| Value| Value createAndGo |inconsistent- | | | | Value| | | --------------+--------------+-----------+-------------+------------- set status |noError see 1|inconsist- |inconsistent-|inconsistent- column to | or | entValue| Value| Value createAndWait |wrongValue | | | --------------+--------------+-----------+-------------+------------- set status |inconsistent- |inconsist- |noError |noError column to | Value| entValue| | active | | | | | | or | | | | | | | |see 2 ->D|see 8 ->D| ->D --------------+--------------+-----------+-------------+------------- set status |inconsistent- |inconsist- |noError |noError ->C column to | Value| entValue| | notInService | | | | | | or | | or | | | | | |see 3 ->C| ->C|see 6 --------------+--------------+-----------+-------------+------------- set status |noError |noError |noError |noError ->A column to | | | | or destroy | ->A| ->A| ->A|see 7 --------------+--------------+-----------+-------------+------------- set any other |see 4 |noError |noError |see 5 column to some| | | | value | | see 1| ->C| ->D --------------+--------------+-----------+-------------+------------- (1) goto B or C, depending on information available to the agent. (2) if other variable bindings included in the same PDU, provide values for all columns which are missing but required, then return noError and goto D. (3) if other variable bindings included in the same PDU, provide values for all columns which are missing but required, then return noError and goto C. (4) at the discretion of the agent, the return value may be either: inconsistentName: because the agent does not choose to create such an instance when the corresponding RowStatus instance does not exist, or inconsistentValue: if the supplied value is inconsistent with the state of some other MIB object's value, or noError: because the agent chooses to create the instance. If noError is returned, then the instance of the status column must also be created, and the new state is B or C, depending on the information available to the agent. If inconsistentName or inconsistentValue is returned, the row remains in state A. (5) depending on the MIB definition for the column/table, either noError or inconsistentValue may be returned. (6) the return value can indicate one of the following errors: wrongValue: because the agent does not support createAndWait, or inconsistentValue: because the agent is unable to take the row out of service at this time, perhaps because it is in use and cannot be de-activated. (7) the return value can indicate the following error: inconsistentValue: because the agent is unable to remove the row at this time, perhaps because it is in use and cannot be de-activated. NOTE: Other processing of the set request may result in a response other than noError being returned, e.g., wrongValue, noCreation, etc. Conceptual Row Creation There are four potential interactions when creating a conceptual row: selecting an instance-identifier which is not in use; creating the conceptual row; initializing any objects for which the agent does not supply a default; and, making the conceptual row available for use by the managed device. Interaction 1: Selecting an Instance-Identifier The algorithm used to select an instance-identifier varies for each conceptual row. In some cases, the instance- identifier is semantically significant, e.g., the destination address of a route, and a management station selects the instance-identifier according to the semantics. In other cases, the instance-identifier is used solely to distinguish conceptual rows, and a management station without specific knowledge of the conceptual row might examine the instances present in order to determine an unused instance-identifier. (This approach may be used, but it is often highly sub-optimal; however, it is also a questionable practice for a naive management station to attempt conceptual row creation.) Alternately, the MIB module which defines the conceptual row might provide one or more objects which provide assistance in determining an unused instance-identifier. For example, if the conceptual row is indexed by an integer-value, then an object having an integer-valued SYNTAX clause might be defined for such a purpose, allowing a management station to issue a management protocol retrieval operation. In order to avoid unnecessary collisions between competing management stations, `adjacent' retrievals of this object should be different. Finally, the management station could select a pseudo-random number to use as the index. In the event that this index was already in use and an inconsistentValue was returned in response to the management protocol set operation, the management station should simply select a new pseudo-random number and retry the operation. A MIB designer should choose between the two latter algorithms based on the size of the table (and therefore the efficiency of each algorithm). For tables in which a large number of entries are expected, it is recommended that a MIB object be defined that returns an acceptable index for creation. For tables with small numbers of entries, it is recommended that the latter pseudo-random index mechanism be used. Interaction 2: Creating the Conceptual Row Once an unused instance-identifier has been selected, the management station determines if it wishes to create and activate the conceptual row in one transaction or in a negotiated set of interactions. Interaction 2a: Creating and Activating the Conceptual Row The management station must first determine the column requirements, i.e., it must determine those columns for which it must or must not provide values. Depending on the complexity of the table and the management station's knowledge of the agent's capabilities, this determination can be made locally by the management station. Alternately, the management station issues a management protocol get operation to examine all columns in the conceptual row that it wishes to create. In response, for each column, there are three possible outcomes: - a value is returned, indicating that some other management station has already created this conceptual row. We return to interaction 1. - the exception `noSuchInstance' is returned, indicating that the agent implements the object-type associated with this column, and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist. For those columns to which the agent provides read-create access, the `noSuchInstance' exception tells the management station that it should supply a value for this column when the conceptual row is to be created. - the exception `noSuchObject' is returned, indicating that the agent does not implement the object-type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval. As such, the management station can not issue any management protocol set operations to create an instance of this column. Once the column requirements have been determined, a management protocol set operation is accordingly issued. This operation also sets the new instance of the status column to `createAndGo'. When the agent processes the set operation, it verifies that it has sufficient information to make the conceptual row available for use by the managed device. The information available to the agent is provided by two sources: the management protocol set operation which creates the conceptual row, and, implementation-specific defaults supplied by the agent (note that an agent must provide implementation-specific defaults for at least those objects which it implements as read-only). If there is sufficient information available, then the conceptual row is created, a `noError' response is returned, the status column is set to `active', and no further interactions are necessary (i.e., interactions 3 and 4 are skipped). If there is insufficient information, then the conceptual row is not created, and the set operation fails with an error of `inconsistentValue'. On this error, the management station can issue a management protocol retrieval operation to determine if this was because it failed to specify a value for a required column, or, because the selected instance of the status column already existed. In the latter case, we return to interaction 1. In the former case, the management station can re-issue the set operation with the additional information, or begin interaction 2 again using `createAndWait' in order to negotiate creation of the conceptual row. NOTE WELL Regardless of the method used to determine the column requirements, it is possible that the management station might deem a column necessary when, in fact, the agent will not allow that particular columnar instance to be created or written. In this case, the management protocol set operation will fail with an error such as `noCreation' or `notWritable'. In this case, the management station decides whether it needs to be able to set a value for that particular columnar instance. If not, the management station re-issues the management protocol set operation, but without setting a value for that particular columnar instance; otherwise, the management station aborts the row creation algorithm. Interaction 2b: Negotiating the Creation of the Conceptual Row The management station issues a management protocol set operation which sets the desired instance of the status column to `createAndWait'. If the agent is unwilling to process a request of this sort, the set operation fails with an error of `wrongValue'. (As a consequence, such an agent must be prepared to accept a single management protocol set operation, i.e., interaction 2a above, containing all of the columns indicated by its column requirements.) Otherwise, the conceptual row is created, a `noError' response is returned, and the status column is immediately set to either `notInService' or `notReady', depending on whether it has sufficient information to make the conceptual row available for use by the managed device. If there is sufficient information available, then the status column is set to `notInService'; otherwise, if there is insufficient information, then the status column is set to `notReady'. Regardless, we proceed to interaction 3. Interaction 3: Initializing non-defaulted Objects The management station must now determine the column requirements. It issues a management protocol get operation to examine all columns in the created conceptual row. In the response, for each column, there are three possible outcomes: - a value is returned, indicating that the agent implements the object-type associated with this column and had sufficient information to provide a value. For those columns to which the agent provides read-create access (and for which the agent allows their values to be changed after their creation), a value return tells the management station that it may issue additional management protocol set operations, if it desires, in order to change the value associated with this column. - the exception `noSuchInstance' is returned, indicating that the agent implements the object-type associated with this column, and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist. However, the agent does not have sufficient information to provide a value, and until a value is provided, the conceptual row may not be made available for use by the managed device. For those columns to which the agent provides read-create access, the `noSuchInstance' exception tells the management station that it must issue additional management protocol set operations, in order to provide a value associated with this column. - the exception `noSuchObject' is returned, indicating that the agent does not implement the object-type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval. As such, the management station can not issue any management protocol set operations to create an instance of this column. If the value associated with the status column is `notReady', then the management station must first deal with all `noSuchInstance' columns, if any. Having done so, the value of the status column becomes `notInService', and we proceed to interaction 4. Interaction 4: Making the Conceptual Row Available Once the management station is satisfied with the values associated with the columns of the conceptual row, it issues a management protocol set operation to set the status column to `active'. If the agent has sufficient information to make the conceptual row available for use by the managed device, the management protocol set operation succeeds (a `noError' response is returned). Otherwise, the management protocol set operation fails with an error of `inconsistentValue'. NOTE WELL A conceptual row having a status column with value `notInService' or `notReady' is unavailable to the managed device. As such, it is possible for the managed device to create its own instances during the time between the management protocol set operation which sets the status column to `createAndWait' and the management protocol set operation which sets the status column to `active'. In this case, when the management protocol set operation is issued to set the status column to `active', the values held in the agent supersede those used by the managed device. If the management station is prevented from setting the status column to `active' (e.g., due to management station or network failure) the conceptual row will be left in the `notInService' or `notReady' state, consuming resources indefinitely. The agent must detect conceptual rows that have been in either state for an abnormally long period of time and remove them. It is the responsibility of the DESCRIPTION clause of the status column to indicate what an abnormally long period of time would be. This period of time should be long enough to allow for human response time (including `think time') between the creation of the conceptual row and the setting of the status to `active'. In the absence of such information in the DESCRIPTION clause, it is suggested that this period be approximately 5 minutes in length. This removal action applies not only to newly- created rows, but also to previously active rows which are set to, and left in, the notInService state for a prolonged period exceeding that which is considered normal for such a conceptual row. Conceptual Row Suspension When a conceptual row is `active', the management station may issue a management protocol set operation which sets the instance of the status column to `notInService'. If the agent is unwilling to do so, the set operation fails with an error of `wrongValue' or `inconsistentValue'. Otherwise, the conceptual row is taken out of service, and a `noError' response is returned. It is the responsibility of the DESCRIPTION clause of the status column to indicate under what circumstances the status column should be taken out of service (e.g., in order for the value of some other column of the same conceptual row to be modified). Conceptual Row Deletion For deletion of conceptual rows, a management protocol set operation is issued which sets the instance of the status column to `destroy'. This request may be made regardless of the current value of the status column (e.g., it is possible to delete conceptual rows which are either `notReady', `notInService' or `active'.) If the operation succeeds, then all instances associated with the conceptual row are immediately removed."; }; typedef TimeStamp { type TimeTicks; description "The value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. When the specific occurrence occurred prior to the last time sysUpTime was zero, then the TimeStamp value is zero. Note that this requires all TimeStamp values to be reset to zero when the value of sysUpTime reaches 497+ days and wraps around to zero."; }; typedef TimeInterval { type Integer32 (0..2147483647); description "A period of time, measured in units of 0.01 seconds."; }; typedef DateAndTime { type OctetString (8 | 11); format "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"; description "A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in big-endian encoding - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present."; }; typedef StorageType { type Enumeration (other(1), volatile(2), nonVolatile(3), permanent(4), readOnly(5)); description "Describes the memory realization of a conceptual row. A row which is volatile(2) is lost upon reboot. A row which is either nonVolatile(3), permanent(4) or readOnly(5), is backed up by stable storage. A row which is permanent(4) can be changed but not deleted. A row which is readOnly(5) cannot be changed nor deleted. If the value of an object with this syntax is either permanent(4) or readOnly(5), it cannot be modified. Conversely, if the value is either other(1), volatile(2) or nonVolatile(3), it cannot be modified to be permanent(4) or readOnly(5). (All illegal modifications result in a 'wrongValue' error.) Every usage of this textual convention is required to specify the columnar objects which a permanent(4) row must at a minimum allow to be writable."; }; typedef TDomain { type ObjectIdentifier; description "Denotes a kind of transport service. Some possible values, such as snmpUDPDomain, are defined in 'Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)'."; }; typedef TAddress { type OctetString (1..255); description "Denotes a transport service address. For snmpUDPDomain, a TAddress is 6 octets long, the initial 4 octets containing the IP-address in network-byte order and the last 2 containing the UDP port in network-byte order. Cosult 'Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)' for further information on snmpUDPDomain."; }; typedef IpAddr { type OctetString (4 | 16); description "The IpAddr type represents a 32-bit internet IPv4 address if it is 4 octets long, or a 128-bit internet IPv6 address if it is 16 octets long, both in network byte-order." }; };
module IRTF-NMRG-SMING-EXTENSIONS irtfNmrgSmingExtensions { // // $RCSfile: IRTF-NMRG-SMING-EXTENSIONS,v $ // $Revision: 1.7 $ // $Author: strauss $ // $Date: 1999/05/07 15:57:27 $ // oid 1.3.6.1.3.1575.1.10; // experimental.1575.1.10 organization "IRTF Network Management Research Group (NMRG), Network Management Group, TU Braunschweig"; contact " Frank Strauss Postal: TU Braunschweig Bueltenweg 74/75 38106 Braunschweig Germany Phone: +49 531 391-3283 EMail: strauss@ibr.cs.tu-bs.de http://www.ibr.cs.tu-bs.de/~strauss/sming/"; description "Core extension definitions for SMIng."; revision { date "1999-05-07"; description "Initial Revision."; }; extension agentcaps { status current; description "The agentcaps extension statement is used to describe an agent's deviation from the compliance statements of the modules it implements. It is designed to be compatible with the SMIv2 AGENT-CAPABILITIES macro. The agentcaps extenstion statement should only be used in the statement body of a module that does not contain any other type or node definitions that do not correspond to an agent implementation. The following ABNF definitions extend the SMIng grammar to include the agentcaps definition: agentcapsStatement = `agentcaps' sep lcIdentifier optsep `{' stmtsep oidStatement stmtsep releaseStatement stmtsep *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) *(includesStatement stmtsep) `}' optsep `;' includesStatement = `includes' sep qlcIdentifier optsep `{' stmtsep *(variationStatement stmtsep) `}' optsep `;' variationStatement = `variation' sep qlcIdentifier optsep `{' stmtsep typeStatement stmtsep writetypeStatement stmtsep accessStatement stmtsep createStatement stmtsep `}' optsep `;' "; reference "RFC 2580, Section 6 describes the SMIv2 compatible AGENT-CAPABILITIES macro."; }; };
TOC |
As experience is gained with a module, it may be desirable to revise that module. However, changes are not allowed if they have any potential to cause interoperability problems between an implementation using an original specification and an implementation using an updated specification(s).
For any change, the module's header MUST be updated to include information about the revision: specifically, a new `revision' statement (The module's revision Statement) must be included in front of the `revision' statements. Furthermore, any necessary changes MUST be applied to other statements, including the `organization' and `contact' statements (The module's organization Statement, The module's contact Statement).
Note that any definition contained in a module is available to be imported by any other module, and is referenced in an `import' statement via the module name. Thus, a module name MUST NOT be changed. Specifically, the module name (e.g., `FIZBIN-MIB' in the example of Usage Example) MUST NOT be changed when revising a module (except to correct typographical errors), and definitions MUST NOT be moved from one module to another.
Also note, that obsolete definitions MUST NOT be removed from modules since their descriptors may still be referenced by other modules, and the object identifiers used to name them MUST never be re-assigned.
A definition may be revised in any of the following ways:
Otherwise, if the semantics of any previous definition are changed (i.e., if a non-editorial change is made to any definition other than those specifically allowed above), then the `oid' statement value associated with that object MUST also be changed.
Note that changing the identifier associated with an existing object is considered a semantic change, as these strings may be used in an `import' statement.
TOC |
While SMIng has a well defined set of statements (The module Statement through The compliance Statement) that are used to specify those aspects of management information commonly regarded as necessary, there may be further information, people wish to express. To describe additional information informally in description statements has the disadvantage, that this information cannot be parsed by any program.
SMIng allows modules to include statements that are unknown to a parser but fulfill some core grammar rules (Statements and Arguments). Furthermore, additional statements may be defined by the `extension' statement (The extension Statement). Extensions can be used in the local module or in other modules, that import the extension. This has some advantages:
The only formal effect of an extension statement definition is to declare its existence and its status. All additional aspects SHOULD be described in the `description' statement:
Some possible extension applications might be:
TOC |
Conversions of SMIv2 modules to SMIng are feasible. The only SMIv2 construct that cannot be mapped to an SMIng statement is the AGENT-CAPABILITIES macro. However, this can be mapped to the `agentcaps' extension. All other constructs and types are directly mappable without loss of information.
Detailed mapping information is subject to a future document.
SMIng is more liberal in some aspects to ensure a more consistent information model and a short grammar with less exceptions. This leads to a limited backwards convertability to SMIv2 of different kinds of identifiers, groups, type definition hierarchies, octet string length limitations, and object identifier values (those with a single sub-identifier). Some other information gets lost when being converted to SMIv2: some occurences of references, units, formats, default values, table indexing information, and table row creation information.
Detailed mapping information is subject to a future document.
Conversions between SMIv1 and SMIng are not covered by this document. Anyhow, conversions between SMIv1 and SMIv2 are subject to SMIv2 and partly described in [14]. Conversions between SMIv2 and SMIng are covered in the sections above.
In few words, conversion from SMIv1 to SMIng is not possible in some cases and without some additional information. Conversion from SMIng to SMIv1 is possible if 64 bit types and floating point data types are not used and if identifiers conform to the SMIv1 restrictions.
TOC |
This document defines a language with which to write and read descriptions of management information. The language itself has no security impact on the Internet.
TOC |
This document is originated as a central part of a master's thesis at the Technical University of Braunschweig, under the guidance of Juergen Schoenwaelder.
Since SMIng represents a successor of SMIv2, a huge amount of paragraphs and phrases are taken from the SMIv2 specifications [2], [3], [4].
Finally, M.T. Rose's work on an XML framework for RFC authors made the writing of an Internet standards document much more feasible.
Thanks to these people and the authors of these documents.
TOC |
[1] | Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", RFC 2119, BCP 14, March 1997. |
[2] | McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M., Waldbusser, S., "Structure of Management Information Version 2 (SMIv2)", RFC 2578, STD 58, April 1999. |
[3] | McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M., Waldbusser, S., "Textual Conventions for SMIv2", RFC 2579, STD 59, April 1999. |
[4] | McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M., Waldbusser, S., "Conformance Statements for SMIv2", RFC 2580, STD 60, April 1999. |
[5] | Rose, M., McCloghrie, K., "Structure and Identification of Management Information for TCP/IP-based Internets", RFC 1155, STD 16, May 1990. |
[6] | Rose, M., McCloghrie, K., "Concise MIB Definitions", RFC 1212, STD 16, March 1991. |
[7] | Rose, M., "A Convention for Defining Traps for use with the SNMP", RFC 1215, March 1991. |
[8] | Crocker, D., Overell, P., "Augmented BNF for Syntax Specifications: ABNF", RFC 2234, November 1997. |
[9] | International Organization for Standardization, "Specification of Abstract Syntax Notation One (ASN.1)", International Standard 8824, December 1987. |
[10] | Harrington, D., Presuhn, R., Wijnen, B., "An Architecture for Describing SNMP Management Frameworks", RFC 2271, January 1999. |
[11] | Institute of Electrical and Electronics Engineers, "IEEE Standard for Binary Floating-Point Arithmetic", ANSI/IEEE Standard 754-1985, August 1985. |
[12] | Yergeau, F., "UTF-8, a transformation format of ISO 10646", RFC 2279, January 1998. |
[13] | Case, J., McCloghrie, K., Rose, M., Waldbusser, S., "Management Information Base for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1907, January 1996. |
[14] | Wijnen, B., Levi, D., "V2ToV1 - Mapping SNMPv2 onto SNMPv1 within a bi-lingual SNMP agent", RFC 2089, January 1997. |
TOC |
Frank Strauss | |
TU Braunschweig | |
Bueltenweg 74/75 | |
38106 Braunschweig | |
Germany | |
Phone: | +49 531 391-3283 |
EMail: | strauss@ibr.cs.tu-bs.de |
URI: | http://www.ibr.cs.tu-bs.de/ |
TOC |
The SMIng grammar conforms to the Augmented Backus-Naur Form (ABNF)[8], with one exception: For readability, keywords are represented as quoted strings, although ABNF would declare these strings to be case-insensitive. Anyhow, SMIng keyword are meant to be case-sensitive.
;; ;; sming.abnf -- SMIng grammar in ABNF notation (RFC 2234). ;; ;; @(#) $Id: sming.abnf,v 1.22 1999/04/20 18:06:07 strauss Exp $ ;; ;; Copyright (C) The Internet Society (1999). All Rights Reserved. ;; smingFile = optsep *(moduleStatement optsep) ;; ;; Statement rules. ;; moduleStatement = moduleKeyword sep ucIdentifier sep lcIdentifier optsep "{" stmtsep *(importStatement stmtsep) oidStatement stmtsep organizationStatement stmtsep contactStatement stmtsep descriptionStatement stmtsep *1(referenceStatement stmtsep) 1*(revisionStatement stmtsep) *(extensionStatement stmtsep) *(typedefStatement stmtsep) *(anyObjectStatement stmtsep) *(notificationStatement stmtsep) *(groupStatement stmtsep) *(complianceStatement stmtsep) "}" optsep ";" extensionStatement = extensionKeyword sep lcIdentifier optsep "{" stmtsep *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" typedefStatement = typedefKeyword sep ucIdentifier optsep "{" stmtsep typedefTypeStatement stmtsep *1(defaultStatement stmtsep) *1(formatStatement stmtsep) *1(unitsStatement stmtsep) *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" anyObjectStatement = nodeStatement / scalarStatement / tableStatement nodeStatement = nodeKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep *1(statusStatement stmtsep) *1(descriptionStatement stmtsep) *1(referenceStatement stmtsep) "}" optsep ";" scalarStatement = scalarKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep typeStatement stmtsep accessStatement stmtsep *1(defaultStatement stmtsep) *1(formatStatement stmtsep) *1(unitsStatement stmtsep) *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" tableStatement = tableKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) rowStatement stmtsep "}" optsep ";" rowStatement = rowKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep anyIndexStatement stmtsep *1(createStatement stmtsep) *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) 1*(columnStatement stmtsep) "}" optsep ";" columnStatement = columnKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep typeStatement stmtsep accessStatement stmtsep *1(defaultStatement stmtsep) *1(formatStatement stmtsep) *1(unitsStatement stmtsep) *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" notificationStatement = notificationKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep *1(objectsStatement stmtsep) *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" groupStatement = groupKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep membersStatement stmtsep *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) "}" optsep ";" complianceStatement = complianceKeyword sep lcIdentifier optsep "{" stmtsep oidStatement stmtsep *1(statusStatement stmtsep) descriptionStatement stmtsep *1(referenceStatement stmtsep) *1(mandatoryStatement stmtsep) *(optionalStatement stmtsep) *(refineStatement stmtsep) "}" optsep ";" importStatement = importKeyword sep ucIdentifier optsep "(" optsep identifierList optsep ")" optsep ";" revisionStatement = revisionKeyword optsep "{" stmtsep dateStatement stmtsep descriptionStatement stmtsep "}" optsep ";" typedefTypeStatement = typeKeyword sep refinedBaseType optsep ";" typeStatement = typeKeyword sep (refinedBaseType / refinedType) optsep ";" writetypeStatement = writetypeKeyword sep (refinedBaseType / refinedType) optsep ";" anyIndexStatement = indexStatement / augmentsStatement / reordersStatement / sparseStatement / expandsStatement indexStatement = indexKeyword *1(sep impliedKeyword) optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" augmentsStatement = augmentsKeyword sep qlcIdentifier optsep ";" reordersStatement = reordersKeyword sep qlcIdentifier *1(sep impliedKeyword) optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" sparseStatement = sparseKeyword sep qlcIdentifier optsep ";" expandsStatement = expandsKeyword sep qlcIdentifier *1(sep impliedKeyword) optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" createStatement = createKeyword *1(optsep createColumns) optsep ";" createColumns = "(" optsep qlcIdentifierList optsep ")" oidStatement = oidKeyword sep objectIdentifier optsep ";" dateStatement = dateKeyword sep date optsep ";" organizationStatement = organizationKeyword sep text optsep ";" contactStatement = contactKeyword sep text optsep ";" formatStatement = formatKeyword sep format optsep ";" unitsStatement = unitsKeyword sep units optsep ";" statusStatement = statusKeyword sep status optsep ";" accessStatement = accessKeyword sep access optsep ";" defaultStatement = defaultKeyword sep anyValue optsep ";" descriptionStatement = descriptionKeyword sep text optsep ";" referenceStatement = referenceKeyword sep text optsep ";" membersStatement = membersKeyword optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" objectsStatement = objectsKeyword optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" mandatoryStatement = mandatoryKeyword optsep "(" optsep qlcIdentifierList optsep ")" optsep ";" optionalStatement = optionalKeyword sep qlcIdentifier optsep "{" descriptionStatement stmtsep "}" optsep ";" refineStatement = refineKeyword sep qlcIdentifier optsep "{" *1(typeStatement stmtsep) *1(writetypeStatement stmtsep) *1(accessStatement stmtsep) descriptionStatement stmtsep "}" optsep ";" ;; ;; ;; refinedBaseType = OctetStringKeyword *1(optsep numberSpec) / ObjectIdentifierKeyword / Integer32Keyword *1(optsep numberSpec) / Unsigned32Keyword *1(optsep numberSpec) / Integer64Keyword *1(optsep numberSpec) / Unsigned64Keyword *1(optsep numberSpec) / Float32Keyword *1(optsep floatSpec) / Float64Keyword *1(optsep floatSpec) / Float128Keyword *1(optsep floatSpec) / EnumerationKeyword namedNumberSpec / BitsKeyword namedNumberSpec refinedType = qucIdentifier *1(optsep anySpec) anySpec = numberSpec / floatSpec numberSpec = "(" optsep numberElement *furtherNumberElement optsep ")" furtherNumberElement = optsep "|" optsep numberElement numberElement = signedNumber *1numberUpperLimit numberUpperLimit = optsep ".." optsep signedNumber floatSpec = "(" optsep floatElement *furtherFloatElement optsep ")" furtherFloatElement = optsep "|" optsep floatElement floatElement = floatValue *1floatUpperLimit floatUpperLimit = optsep ".." optsep floatValue namedNumberSpec = "(" optsep namedNumberList optsep ")" namedNumberList = namedNumberItem *(optsep "," optsep namedNumberItem) *1(optsep ",") namedNumberItem = lcIdentifier optsep "(" optsep number optsep ")" identifierList = identifier *(optsep "," optsep identifier) *1(optsep ",") qIdentifierList = qIdentifier *(optsep "," optsep qIdentifier) *1(optsep ",") qlcIdentifierList = qlcIdentifier *(optsep "," optsep qlcIdentifier) *1(optsep ",") bitsValue = "(" optsep bitsList optsep ")" bitsList = *1(lcIdentifier *(optsep "," optsep lcIdentifier)) *1(optsep ",") ;; ;; Other basic rules. ;; identifier = ucIdentifier / lcIdentifier qIdentifier = qucIdentifier / qlcIdentifier ucIdentifier = ucAlpha *63(ALPHA / DIGIT / "-") qucIdentifier = *1(ucIdentifier "::") ucIdentifier lcIdentifier = lcAlpha *63(ALPHA / DIGIT / "-") qlcIdentifier = *1(ucIdentifier "::") lcIdentifier text = textSegment *(optsep textSegment) textSegment = DQUOTE *textAtom DQUOTE textAtom = textVChar / HTAB / SP / lineBreak date = DQUOTE 4DIGIT "-" 2DIGIT "-" 2DIGIT *1(" " 2DIGIT ":" 2DIGIT) DQUOTE ; always in UTC format = textSegment units = textSegment anyValue = bitsValue / negativeNumber / hexadecimalNumber / floatValue / text / objectIdentifier ; Note: `objectIdentifer' includes the ; syntax of enumeration labels and postive ; numbers. They are not named literally to ; avoid reduce/reduce conflicts when ; building LR parsers based on this ; grammar. status = currentKeyword / deprecatedKeyword / obsoleteKeyword access = noaccessKeyword / notifyonlyKeyword / readonlyKeyword / readwriteKeyword objectIdentifier = (qlcIdentifier / subid) *127("." subid) subid = decimalNumber number = hexadecimalNumber / decimalNumber negativeNumber = "-" decimalNumber signedNumber = number / negativeNumber decimalNumber = "0" / (nonZeroDigit *DIGIT) zeroDecimalNumber = 1*DIGIT hexadecimalNumber = "0x" 1*(HEXDIG HEXDIG) floatValue = neginfKeyword / posinfKeyword / snanKeyword / qnanKeyword / signedNumber "." zeroDecimalNumber *1("E" ("+"/"-") zeroDecimalNumber) ;; ;; Rules to skip unknown statements ;; with arbitrary arguments and blocks. ;; unknownStatement = unknownKeyword optsep *unknownArgument optsep ";" unknownArgument = ("(" optsep unknownList optsep ")") / ("{" optsep *unknownStatement optsep "}") / qucIdentifier / anyValue / anySpec unknownList = namedNumberList / qIdentifierList unknownKeyword = lcIdentifier ;; ;; Keyword rules. ;; ;; Typically, keywords are represented by tokens returned from the ;; lexical analyzer. Note, that the lexer has to be stateful to ;; distinguish keywords from identifiers depending on the context ;; position in the input stream. ;; ;; Also note, that these keyword definitions are represented in ;; cleartext for readability, while SMIng keywords are meant to be ;; case-sensitive, although ABNF makes quoted strings like these to ;; be case-insensitive. ;; ;; Statement keywords. moduleKeyword = "module" importKeyword = "import" revisionKeyword = "revision" oidKeyword = "oid" dateKeyword = "date" organizationKeyword = "organization" contactKeyword = "contact" descriptionKeyword = "description" referenceKeyword = "reference" extensionKeyword = "extension" typedefKeyword = "typedef" typeKeyword = "type" writetypeKeyword = "writetype" nodeKeyword = "node" scalarKeyword = "scalar" tableKeyword = "table" columnKeyword = "column" rowKeyword = "row" notificationKeyword = "notification" groupKeyword = "group" complianceKeyword = "compliance" formatKeyword = "format" unitsKeyword = "units" statusKeyword = "status" accessKeyword = "access" defaultKeyword = "default" impliedKeyword = "implied" indexKeyword = "index" augmentsKeyword = "augments" reordersKeyword = "reorders" sparseKeyword = "sparse" expandsKeyword = "expands" createKeyword = "create" membersKeyword = "members" objectsKeyword = "objects" mandatoryKeyword = "mandatory" optionalKeyword = "optional" refineKeyword = "refine" ;; Base type keywords. OctetStringKeyword = "OctetString" ObjectIdentifierKeyword = "ObjectIdentifier" Integer32Keyword = "Integer32" Unsigned32Keyword = "Unsigned32" Integer64Keyword = "Integer64" Unsigned64Keyword = "Unsigned64" Float32Keyword = "Float32" Float64Keyword = "Float64" Float128Keyword = "Float128" BitsKeyword = "Bits" EnumerationKeyword = "Enumeration" ;; Status keyword. currentKeyword = "current" deprecatedKeyword = "deprecated" obsoleteKeyword = "obsolete" ;; Access keywords. noaccessKeyword = "noaccess" notifyonlyKeyword = "notifyonly" readonlyKeyword = "readonly" readwriteKeyword = "readwrite" ;; Special floating point values' keywords. neginfKeyword = "neginf" posinfKeyword = "posinf" snanKeyword = "snan" qnanKeyword = "qnan" ;; ;; Some low level rules. ;; These tokens are typically skipped by the lexical analyzer. ;; sep = 1*(comment / lineBreak / WSP) ; unconditional separator optsep = *(comment / lineBreak / WSP) stmtsep = *(comment / lineBreak / WSP / unknownStatement) comment = "//" *(WSP / VCHAR) lineBreak lineBreak = CRLF / LF ;; ;; Encoding specific rules. ;; textVChar = %x21 / %x23-7E ; any VCHAR except DQUOTE ucAlpha = %x41-5A lcAlpha = %x61-7A nonZeroDigit = %x31-39 ;; ;; RFC 2234 core rules. ;; ALPHA = %x41-5A / %x61-7A ; A-Z / a-z CR = %x0D ; carriage return CRLF = CR LF ; Internet standard newline DIGIT = %x30-39 ; 0-9 DQUOTE = %x22 ; " (Double Quote) HEXDIG = DIGIT / "A" / "B" / "C" / "D" / "E" / "F" HTAB = %x09 ; horizontal tab LF = %x0A ; linefeed SP = %x20 ; space VCHAR = %x21-7E ; visible (printing) characters WSP = SP / HTAB ; white space ;; ;; EOF ;;
TOC |
- columnar object:
- An object in a table row that may have zero, one or more object instances. Instances are identified by using the values of `indexing objects' as `instance identifier'.
- extension:
- The SMIng `extension' statement can be used to define new statements. Extensions can express annotations to existent management information, agent capabilities known from SMIv2, or arbitrary other information. See SMIng Language Extensibility for details.
- identifier:
- The name of any definition, either a module, type, node, scalar object, table, row, columnar object, notification, group, compliance, a named number of an enumeration or bits type or any construct defined by an SMIng extension. Every identifier starts with an upper-case or lower-case character, followed by letters, digits and hyphens, but without consecutive or trailing hyphens. The length of an identifier MUST NOT exceed 64 characters. Note that SMIng keywords may be used as identifiers, though it's NOT RECOMMENDED. See also Identifiers.
- indexing objects:
- A Table may contain multiple instances of single columnar objects. That is, there may be multiple rows. The table's `indexing objects' are used to unambiguously distinguish the rows of a table. A special encoding of their values represents the columns' instance-identifier, and thus identifies the row.
- instance-identifier:
- That part of an object identifier value, that is used to unambiguously identify an instance of an object. For scalar objects, the instance-identifier is `0'. For columnar objects, the instance-identifier is built from the values of the `indexing objects'. See also Scalar and Columnar Objects' Instances.
- module:
- A module is the container of inter-related management information, either managed objects or other definitions like type definitions or annotations. A module has to conform the SMIng grammar and semantics described by this document. A module represents a namespace in which local definitions are available and external definitions have to be imported.
- named number:
- Values of `Enumeration' types (Enumeration) and single elements of `Bits' (Bits) types are integer numbers, each associated with an identifers. Those number-identifier pairs are called `named numbers'.
- object:
- A leaf definition in the object identifier tree, that represents a class of object instances. Objects are exactly those definitions declared by the SMIng keywords `scalar' or `column'.
- object identifier:
- Management information is organized in a tree of nodes. Each node is unambiguously identified by an `object identifier', that consists of a sequence of integer numbers (`sub-identifiers') which represent the path of nodes from the root to the addressed node in the tree. See also The Information Model.
- row:
- The kind of node used to group columnar objects of a table. Some significant information on table indexing and information used for row creation and deletion is associated with a table's row definition.
- scalar object:
- An object that has zero or one object instance.
- sub-identifier:
- A single component of an object identifier. There are at most 128 sub-identifiers in an object identifier value and each sub-identifier has a maximum value of 2^32-1 (4294967295).
- table:
- The kind of node used to group management information that is organized in a sequence of rows.
TOC |
Copyright (C) The Internet Society (1999). All Rights Reserved.
This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implmentation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.
The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.